DragonWave Inc.
160
Horizon Compact Plus Release 1.0.1
Wireless Ethernet Product User Manual
– Volume 2
CLI Command
Description
set radio loopback [on | off] <timeout>
<network>
sets the radio loop back[on|off]. If the user doesn't supply
the optional parameter [network], then the modem data
path will be disabled.
set radio transmitter state [on | off] [mute
time (seconds)]
allows user to mute/unmute the radio transmitter.
[transmitter state] is enabled or disabled.
set radius server host [index] [server addr]
sets the host address for server specified by [index].
set radius server key [index] [key]
sets the shared key for server specified by [index].
set radius super user authentication
[On|Off]
sets the Radius Authentication Strictness mode. OFF:
Super User can login using flash password. ON: No one
can login without Radius.
set redundancy link monitor parameters
sets redundancy link monitor parameter (both hsb_1wire
and hsb_2wire).
set redundancy link switch parameters
sets redundancy hard error monitor parameter for link
establishing.
set redundancy mode
allows
the
user
to
set
system
redundancy
[primary_hsb_1wire
|
secondary_hsb_1wire
|
primary_hsb_2wire | secondary_hsb_2wire | primary_x2 |
secondary_x2 | normal].
set
redundancy
override
[primary
|
secondary | manual | auto ]
set redundancy standby enet state
allows the user to set required action on port1 of
primary_hsb_2wire or secondary_hsb_2wire node when it
enters standby state. Allowed actions are 'on', 'off' or
'pulse'.
set redundancy state switch
allows the user to force a change in the redundancy state
when the override mode is 'auto' or 'manual'. The user input
is not stored in the system and set to off after the state
change.
set rls [on/off] | [basic|advanced]
sets the RLS mode on|off and optionally basic|advanced.
set rls link control [on/off]
sets the RLS user link enable option. When this is set to
'On' the user has to explicitly enable the link after it
recovers from a fault
set rls link enable [on/off]
sets the RLS global link enable status, if on and no link
error exists the link will be enabled.
set rls link monitor parameters [mk erred
blks] [brk erred blks] [mk samples] [brk
samples] [mk sample time] [brk sample
time] [brk sample rst time]
sets the RLS link monitor low-level parameters
set rls make rsl [make rsl threshold] [rsl mk
sample time sec]
sets the RLS make RSL threshold and sample period,
where: [make rsl threshold] : the minimum rsl threshold
to establish the link [make rsl sample period]: the time the
link rsl must be above the threshold to
establish the link.
set rls port group
enables the user to configure which port or ports are to be
monitored and shut down when an RLS event occurs.