Required Action
Steps
View bandwidth record
thresholds
This command returns the bandwidth record settings.
Sequence:
get bandwidth record thresholds
press Enter
The system responds:
Bandwidth Utilization Thresholds:
10 20 30 40 50 60 70 80 90 95
Start bandwidth logging
This command turns logging on or off. Note that reports are saved to
flash memory irresepective of whether this is on or off.
Sequence:
set bandwidth record logging [on|off]
press Enter
The system responds:
Bandwidth utilization logging to both event log and syslog set to
‘on|off’
View status of bandwidth
logging
This command will return the logging status.
Sequence:
get bandwidth record logging
press Enter
The system responds:
Bandwidth logging to syslog and flashlog set to ‘on|off’
View the administrative status
of bandwidth logging
The command will return the administrative status of bandwidth logging.
Also shown is the operational status, which can be off, when redundancy
mode “secondary_hsb_1wire”, or WLAG wireless link aggregation mode
(x2)
“secondary_x2” options are configured.
Note that any redundancy
related command is not supported in this release.
Sequence:
get bandwidth record admin
press Enter
The system responds:
Bandwidth logging admin status set to ‘on’
Bandwidth logging oper status is ‘off’
Reason: disabled for secondary_hsb_1wire