DragonWave Inc.
52
Horizon Compact Plus Release 1.0.1
Wireless Ethernet Product User Manual
– Volume 2
Required Action
Steps
Configure system mode
Sets the system mode (channel bandwidth, maximum throughput
speed and modulation scheme). You can only select any one of the
modes shown as available when the
get system mode
command is
used.
Sequence:
set system mode < hy[bandwidth]_[throughput]_[modulation]>
Where
[bandwidth]
is the channel bandwidth of the configured
radio band;
[throughput]
is the maximum throughput capability in
Mbps;
[modulation]
is the modulation scheme.
Example:
set system mode hy50_67_qpsk
press Enter
(50 MHz channel bandwidth, 67 Mbps throughput and QPSK
modulation.
System responds:
System mode set to :hy50_67_qpsk
Save changes to mib
Saves the MIB to RAM. Perform this command to save setting
changes to non-volatile memory.
Sequence:
save mib
press Enter
The system responds:
MIB saved successfully.
Reset system
A system reset is required to activate this feature.
Sequence
reset system
press Enter
The system responds:
Are you sure you want to reset? Y(yes) or N(no)
press
Y
The system will proceed to reset. You will have to log on again to
regain access.
Note that all required radio parameters need to be correctly set for the system to be functional.
See Volume 1 of this manual for basic configuration procedures.