August 2009
3 -
Cafitesse 100 Next Generation
Errors
No. Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Priority
40
1BIB: BIB empty
>1BIB: Left BIB
empty
2)
BIB Empty sen-
sor
Automatically
when the sensor
detects
that the BIB is
not empty
Error visi-
ble on all
machine
versions.
The beep
of this
error is
also gene-
rated
when the
error is
reset
Float in B2 dosing unit defec
-
tive
Wiring incorrect or connections
defective
Empty sensor defective
MCB defective
1.
2.
3.
4.
Replace the product pack
Check wiring or replace
conntections
(see chapter 5K)
Replace empty detection as-
sembly (see chapter 5F)
Replace MCB
(see chapter 5K)
1.
2.
3.
4.
55
41
Reserved
42
>1BIB; right BIB
empty
2)
BIB Empty sen-
sor
Automatically
when the sensor
detects
that the BIB is full
The beep
of this
error is
also gene-
rated
when the
error is
reset
Float in B2 dosing unit defec
-
tive
Wiring incorrect or connections
defective
Empty sensor defective
MCB defective
1.
2.
3.
4.
Replace the product pack
Check wiring or replace
conntections
(see chapter 5K)
Replace empty detection as-
sembly (see chapter 5F)
Replace MCB (see chapter 5K)
1.
2.
3.
4.
55
43
1BIB: B2 defec-
tive
>1BIB: left B2
defective
2)
B2 current too
high or too low
Lock/clear
button
1)
(locking
error:
remains
active after
it occurred)
Wiring incorrect or connections
defective
MCB defective
B2 coil defective
1.
2.
3.
Check wiring or replace con-
nections
(see chapter 5K)
Replace MCB
(see chapter 5K)
Replace B2 coil
(see chapter
5C)
1.
2.
3.
100
44
Reserved
1)
Errors are reset by pressing the Lock/clear button in cleaner-, operator-, service- or development mode is shown
2)
Not valid for Cafitesse 100 NG
3)
Valid for Cafitesse 120 NG only
Summary of Contents for Cafitesse 110
Page 2: ... 2009 Douwe Egberts Coffee Systems International DRAFT Version August 2009 D R A F T ...
Page 22: ...D R A F T Cafitesse 100 Next Generation Installation Putting into operation 2 20 August 2009 ...
Page 54: ...Cafitesse 100 Next Generation Programming 4 20 August 2009 ...
Page 58: ...D R A F T Cafitesse 100 Next Generation Functions Overview of assemblies 5 August 2009 ...
Page 71: ...Cafitesse 100 Next Generation Functions water system August 2009 5A 13 ...
Page 82: ...Cafitesse 100 Next Generation Functions dosing system 5C 10 August 2009 ...
Page 93: ......