Disassembly of the heating element
Undo nut (6), lock washer (7) and ground cable
(8) from the earthing sheet heating element (fig.
6).
Undo the black cables from the plug with the
special tool (fig. 7).
Remove the heating element (9) and pull the
black cables (10) through the boiler lid (11)
(fig.
8)
.
On assembly, note the following:
Make sure that you do not forget to install the tube
washed (12) with the expansion pipe (fig. 8).
Hook the dispenser cover plate at the rear into the
corresponding grip (see chapter A.2.3).
Note:
The reassembly is carried out in
reverse order.
•
•
•