Install antenna by threading it on
the connector. Locate receiver in
close proximity to the ED 800 unit.
Position antenna so that it is clear
of metal structures. Anchor the
receiver permanently.
Anchor backplate securely to wall.
Tighten screws through holes in cover
plate with 5/64" hex key.
6 - 32 Wall switch mounting screw.
10
open
5
1
2
3
4
CODE SWITCH
6
7
9
8
ED800-21
08102710 05/07
3
2
1
CODE SWITCH
6
4
5
open
7
8
10
9
7
NC
8
6
C
VESTIBULE
5
BUSY SWING (SAFETY)
2
+12VDC
4
OPEN TRIGGER
3
1
GROUND
BLACK
RED
GRAY
GRAY
NOTE: Be sure receiver unit is kept away from direct moisture.
After installation is complete, check for proper operation. The transmitter should provide reliable
operation from a distance of about 50 feet, however the environment and location of both transmitter and
receiver will affect range.
Connect wires according to following
diagram.
800RFR Radio Frequency Receiver
The 800RFR RF Receiver can be used on applications where it is not practical to run
wires from a switch to the ED 800 unit.
A code must be selected to insure the receiver is only activated by the intended
transmitter(s). This is determined by the positions of the 10 small switches numbered
1 through 10 located on the receiver board. To gain access to the switch, remove the
top section of the case. Any combination of on (closed) or off (open) positions can be
selected by using a small screwdriver or ball point pen. It is strongly recommended
that the following codes be avoided: all on; all off; 2, 4, 6, 8, 10 on; or 1, 3, 5, 7, 9, on.
These codes are frequently used and create the possibility of false operation. After
selecting the code be sure it is recorded so that it may be duplicated in any transmitter
intended to operate the door.
WS/RFT-1Wall Switch
The WS/RFT-1 wall switch with radio frequency transmitter is used in conjunction
with the 800RFR radio frequency receiver. The wall switch transmitter must be located
within a distance of 50 feet from the receiver. The WS/RFT-1 is suitable for outdoor
use, however it must not be exposed to direct moisture. Anchor the backplate of the
wall switch securely to the mounting surface at a height approximately 42" above the
finished floor.
Select the code for the transmitter. The code must
be identical to the code for the receiver which is
intended to be signalled. Refer to code selection
for 800RFR Radio Frequency Receiver. Connect the 9
volt battery at this time.
The replacement battery is 9 volt NEDA 1604
(Eveready 216 or equivalent).
NO
NOTE:
Flush Mount Assembly Kit also available
RE
CE
IV
E
R
800R
FR
Summary of Contents for ED800 J