ED800-20
08102710 05/07
OPEN TRIGGER
WS-1 Wall Switch
FS-1 Frame Switch
The open trigger is created by providing a dry, normally open circuit , which is momentarily closed
to signal the ED 800. Contact is made between "OPEN TRIGGER" and "GROUND".
Typical Wall Switch or Frame switch wiring diagram.
WS-1 WALL SWITCH
When considering the location
of the 800 WS-1 Wall Switch,
sufficient distance should be
allowed between the switch
and the door, to allow for the
door to open.
FS-1 FRAME SWITCH
The FS-1 Frame Switch is
designed to be installed in a
metal door frame with a
minimum width of 1 3/4".
NOTE: Generally, a
junction box is not used
with this type of switch
5
ED 800
4
Inside Switch
C
NC
8
7
6
Outside Switch
BUSY SWING (SAFETY)
NO
GROUND
OPEN TRIGGER
+12VDC
3
2
1
Tighten screws through holes in
cover plate with 5/64" hex key
FINISHED FLOOR
42" APPROXIMATE CL
Tighten screws through holes in
cover plate with 3/32" hex key
4x4 or 2x4 Junction box
(by others)
VESTIBULE
4x4 box mounting screws
42" APPROXIMATE CL
6-32 screw plastic inserts
6 x 32 wall switch mounting screws
FINISHED
FLOOR
Summary of Contents for ED800 J
Page 26: ......