ATTACHMENT OF COMPONENTS TO UNREINFORCED
INDIVIDUAL DOOR MANUFACTURER'S LISTINGS.
ALTERNATIVE METHOD IS IDENTIFIED IN THE
COMPOSITE TYPE FIRE DOORS, UNLESS AN
DOORS AND TO WOOD OR PLASTIC FACED
4. CAUTION: SEX NUTS ARE REQUIRED FOR
ED800-11
ED 800T - TRACK INSTALLATION TEMPLATE & MOUNTING INSTRUCTIONS
Prepare door and frame according to template.
08102710 05/07
ED800-3 Rev.08/04
Remove two (2) cover screws and cover. Disconnect cover ground wire at base plate. Loosen,
but do not remove end cap screws and slide end caps off.
Note:
Re-install end caps, cover ground wire and cover after installation is complete. Push-in emblems
or logo decals can be applied to hide cover screws if needed.
COVER
END CAP
END CAP
WITH
SWITCHES
GROUND WIRE FOR COVER
END CAP
SCREW
(LEFT HAND MOUNT SHOWN)
(100)
1/2
(597)
(13)
(21)
13/16
3. RIGHT HAND DOOR SHOWN.
BOTTOM OF FRAME
NOTES:
C OF HINGE
1. DO NOT SCALE DRAWING.
2. DIMENSIONS ARE IN INCHES/(MM).
FOR 1/4-20 MACHINE SCREWS USE No.7 (0.201") DRILL
FOR No. 14 WOOD SCREWS USE 5/32" DRILL
FIVE (5) HOLES IN FRAME FOR PLATE
FOR 1/4-20 MACHINE SCREWS USE No.7 (0.201") DRILL
FOR No.14 WOOD SCREWS USE 5/32" DRILL
FOR SEX NUTS USE 3/8" DRILL
TWO (2) HOLES IN DOOR FOR TRACK
3-15/16
23-1/2
4-3/8
(111)
8-13/16
(224)
7/8" DIA. HOLE FOR
WIRE ACCESS
MINIMUM TO CEILING 4-5/8"
"A"
"B"
1
(25)
15/16
(24)
5. MAXIMUM OPENING ANGLE 115°.
6. DOORS AND FRAMES MUST BE PROPERLY REINFORCED.
3-1/4
(83)
1-7/16
(37)
PIVOT
7/16"
1"
(11)
(25)
3/4" OFFSET
DIM. "A"
DIM. "B"
4-5/16"
(106)
4-7/8"
(124)
4-1/2"
WIDE HINGE
7. AUXILIARY STOP, (BY OTHERS) ARE REQUIRED AT 115° FOR
INSTALLATIONS WHERE DOOR CAN OPEN FURTHER THEN 115°