52
IMPORTANT:
The memory card must be completely inserted with the contacts facing upwards.
The insertion and removal of the memory must be carried out with the EL6 disconnected.
ADVANCE KEY DISABLING
ACCESS CODE 225
Through access code 255 the ADVAN key is disabled during programme execution.
Every time this access code is activated, the key is activated or disabled displaying the message
"YES" to activate and "NO" to disable. Initialization with the key activated.
MAXIMUM ADMISSIBLE WATER LEVEL DURING SPIN
ACCESS CODE 230
Through the access code 230 the maximum water level allowed in the tank can be displayed
and/or modified during the slow and fast spin execution phase, initialised in 2 cm.
The screen will display:
SPIN LEVEL cm 2
It is not changed by pressing RESET, anyway if you want to change the value, press ENTER
followed by new values and then ENTER again.
The admissible values range from 2 to 60cm
SOFTWARE VERSION
Press the STOP and RESET keys simultaneously and the screen will display the installed software
version.
Example:
VERS.
EL6
8.0.6
NUMBER OF R.P.M OF THE DRUM
By pressing the key INS during the execution of a programme, the screen displays the number of
r.p.m. to which the engine has been programmed for the current step.
Example:
MOT. R.P.M. 500