WRM-10P S2 USER’S MANUAL REV 1.0
44
3.10 Performing a Diagnostic Test
In diagnostic mode, the WRM can run a resistance test and then display the sense voltages and
test current on the screen. This feature can be used to verify the WRM’s voltage and current
readings against an external meter. Follow the steps below to perform a diagnostic test:
a.
Start from the “START-UP” menu:
Press the
[3]
key (
DIAGNOSTICS
).
b.
The following warning screen will be displayed:
Press any key to continue.
c.
The following screen will be displayed:
Press the
[START]
key.
d.
The following screen will be displayed:
- USER DIAG TEST -
I = --
V1 = --
V2 = --
** XFMR ENERGIZED! **
- USER DIAG TEST -
"START" TO RUN TEST
OR
"STOP" TO ABORT
**********WARNING**********
DANGEROUS FLASH-OVER
WILL OCCUR IF CABLES
ARE DISCONNECTED!
***************************
1.RUN TEST
2.TEST RECORDS
3.DIAGNOSTICS
4.SETUP