background image

Digital

 

Monitoring

 

Products 

CellCom‑LTE Programming and Installation Guide

2

Programming (PROG) Connection

A 4‑pin programming header is provided to connect a keypad when using a DMP Model 330 programming cable. 

This provides a quick and easy connection for programming the communicator. For 24 VDC applications using the 

communicator, connect the keypad using a Model 330‑24 4‑wire programming harness with an in‑line resistor. After 

programming is complete, remove the keypad.

Caution:

 If connecting to a 24 VDC control panel, do not connect a keypad using a Model 330 harness.

Tamper

The tamper is pressed when the cover of the communicator is secured onto the enclosure. When the cover is 

removed, the communicator sends a tamper trouble message to the central station.

Reset Button

The reset button is located on the upper right side of the circuit board and is used to reset the communicator. After 

resetting the communicator, begin programming within 30 minutes. If you wait longer than 30 minutes, reset the 

communicator again.

Note:

 After the panel is reset, cell suppression is disabled for 30 minutes.

Load Button

Firmware can be updated with the programming header. Firmware updates are available for download, free of charge, 

on the DMP Dealer Direct website a

DMP.com/Dealer_Direct

.

Caution:

 Do not connect a Model 401 to the communicator if using 24 V power.

Performing a Firmware Update

To update the communicator with a new firmware version, complete the following steps at the protected premise:

399 Programming Cable

1.   Connect a DMP 399 Cable from the programming header to the serial port of your PC operating Remote Link 

and containing the communicator RU file.

2.  Start Remote Link and create or open the account that matches the communicator to be updated.
3.  Set the connection information type to direct with a baud rate of 

38400

 and choose the appropriate COM port.

4.   Select 

Panel > Remote Update

, then select the correct RU file for the communicator.

5.  Press and hold the load button, then press and release the reset button.
6.  Release the load button and select 

<Update>

 in Remote Link.

7.   After the firmware update is completed, remove the 399 cable and press the reset button to resume normal 

operation.

Model 401 USB Flash Module

When loading the firmware RU file onto a USB drive, place the file in the root directory of the USB drive. The update 

cannot be inside a folder. Format the USB drive as FAT32.
Place only one firmware file in the root directory. If more than one RU file exists on the USB drive, the communicator 

will choose the RU file with the most recent date modified.

Caution

: DualCom, CellCom, iCom, and XTL+ do not use the same RU files. Using the wrong RU file for the update 

will cause the communicator to stop working until the correct RU file is used to flash the firmware.

1.  Connect the USB flash drive to the Model 401. 
2.  Press and hold the reset button on the communicator. You will continue to hold reset until step 6.
3.  Connect the assembly to the communicator’s programming header.
4.  Press and release the button on the Model 401.
5.  With your finger still on RESET, press and hold the load button. Continue to hold LOAD until step 8.
6.  Release the reset button.
7.  Press and release the button on the Model 401.
8.  When the green LED on the Model 401 starts a slow flash, release the load button. The slow flash will last 

5 minutes, then the green LED will become steady, indicating the firmware version is updated. 

Note:

 If the LED blinks rapidly, the update was unsuccessful. Press and release RESET. Begin again at step 1

9.  Press and hold RESET. Remove the Model 401, then release RESET to resume normal operation.

In the event the Model 401 USB Flash Module is inadvertently removed from the communicator before the update 

finishes, repeat steps 1‑9.

Summary of Contents for CellCom LTE Series

Page 1: ...CellCom LTE V Series Communicator Digital Monitoring Products Inc 2020 PROGRAMMING AND INSTALLATION GUIDE...

Page 2: ...n 14 Programming 15 Before You Begin 15 Getting Started 15 Programming Menu 15 Reset Timeout 16 Special Keys 16 Letters and Special Characters 17 Current Programming 17 Initialization 18 Clear All Cod...

Page 3: ...Message To Transmit 27 Output Number 27 Output Action 28 Swinger Bypass 28 Cross Zone 28 Receiver Routing 28 Zone Number 28 Stop 29 Set Lockout Code 29 Stop 29 Set Lockout Code 29 Appendix 30 ECP Pass...

Page 4: ......

Page 5: ...COMPONENTS Terminals Power Connection Terminals The communicator may be powered from the 12 VDC or 24 VDC auxiliary output of the control panel Observe polarity and use 18 22 AWG wire to connect the c...

Page 6: ...tion information type to direct with a baud rate of 38400 and choose the appropriate COM port 4 Select Panel Remote Update then select the correct RU file for the communicator 5 Press and hold the loa...

Page 7: ...IVITY OPERATION Green Steady Communicator Disarmed Primary Power OK No Light No Power Red Steady Communicator Armed Primary Power OK ECP and DSC Passthru Perform an ECP or DSC Passthru and communicate...

Page 8: ...place to protect the communicator from damage due to tampering or the elements It is not necessary to remove the PCB when installing the communicator Figure 1 System Components DC Z1 Z2 Z3 G T R Z4 O1...

Page 9: ...nnect the Antenna Place the antenna onto the SMA connector Refer back to Figure 1 Twist the antenna until it is securely tightened Replace the housing cover on the mounted base Be sure to not damage a...

Page 10: ...y Use a normally closed output on a burglary control panel to indicate a burglary alarm The communicator zone should be programmed with a zone name and burglary zone type When the output on the contro...

Page 11: ...adence type zone number and type of message sent to the receiver The communicator generates zones 5 and 6 using the zone name of zone 4 to send to the central station Zones 5 and 6 cannot be preprogra...

Page 12: ...O1 O2 Use 18 22 AWG for Power Supply connection 1k Z4 DMP Panel 12 VDC Aux Output ADEMCO Panel 12 VDC Aux Output BELL 12 VDC BELL NAPCO Panel 12VDC Aux Output BELL 12 VDC BELL DSC Panel 12 24 VDC Aux...

Page 13: ...n about configuring ECP Passthru refer to COM Series How To Guide ECP Passthru LT 2209 PROG B R RESET LOAD DC Z1 Z2 Z3 G T R Z4 O1 O2 DualCom 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2...

Page 14: ...on 2 0 or higher VISTA 15 Yes No No No No VISTA 15P Yes Yes Yes Yes Firmware version 5 2 or higher VISTA 20SE Rev 12 or higher No No No No VISTA 20P Yes Yes Yes Yes Firmware version 5 2 or higer VISTA...

Page 15: ...nnection Model 330 DSC PC LINK 1 CON 4 YELLOW GREEN YELLOW GREEN TAB UP Figure 9 DSC Passthru Wiring COMMUNICATOR TO DSC WIRING Communicator Terminal DSC Terminal DC RED DC BLK Z4 YEL Z4 GRN T or T1 T...

Page 16: ...tput or remote arming output in output options when programming the communicator See Armed Output or Remote Arming Output The communicator output connections can be used with any of the applications l...

Page 17: ...minal 23 on the control panel 4 Connect the R ring terminal on the communicator to terminal 24 on the control panel 5 Power the communicator by connecting its terminal 12V to terminal 5 on the control...

Page 18: ...o the panel Press Yes 13 Configure additional options as needed then press Save Tech APP Activation 1 Go to the Customer Summary Systems 2 Tap the Add icon 3 Enter the System Name 4 In System Type sel...

Page 19: ...ed or deleted in panel programming To revert the default code to 99 use the Clear All Codes option found in the Initialization menu Panels ship with the master code on the serial number label in paren...

Page 20: ...ress CMD to advance to the next step CMD is also used to enter information into the communicator s memory such as an IP address or a zone name Press CMD after entering information Back Arrow Use the b...

Page 21: ...er character or press CMD if finished NUMBER SELECT KEY 1 SELECT KEY 2 SELECT KEY 3 SELECT KEY 4 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 P Q R 7 S T U 8 V W X 9 Y Z space _ 0 Standard Keyboard Press...

Page 22: ...NG Choose NO to leave existing zone information intact Choose YES to set all zones in the system to UNUSED CLEAR COMMUNICATION Choose NO to leave existing communication programming intact Choose YES t...

Page 23: ...ly if this option is used FAIL TIME MINUTES Fail time allows the SCS 1R or SCS VR receivers to miss a defined number of check ins before logging that the panel is missing For example if cell check in...

Page 24: ...the receiver The default is NO Supervisory Trouble Reports Choose YES to enable Supervisory Trouble Trouble Restoral Force Armed Late to Close and Fault reports to be sent to this receiver Choose NO...

Page 25: ...remotely The default is YES Choose NO to disable remote disarming REMOTE OPTIONS RMT KEY DISARM NO YES SYSTEM REPORTS This option allows you to select which reports the communicator sends to the rece...

Page 26: ...zone time can be from 4 250 seconds in one second increments Enter 0 to disable the cross zone time feature See Cross Zoning POWER FAIL DELAY Enter the time allowed for a power failure to occur befor...

Page 27: ...to enable communication between the communicator and an Ademco Honeywell panel using the Z4 terminals Using the Ademco Honeywell ECP Bus the communicator can add delete and change user codes as well a...

Page 28: ...e can be 1 15 minutes Enter 0 to provide continuous output Note The output is cutoff within 60 seconds of the programmed cutoff time The cutoff timer is shared by all outputs If a second output trips...

Page 29: ...bad zones If a closing report is sent the user number is indicated as SCH on the SCS 1R or SCS VR receivers Choose NO to disable automatic arming for this area The default is NO Bad Zones At the time...

Page 30: ...e responses are made automatically for the zone There are 12 zone types to choose from including Blank To select a new zone type press any select area The display lists the four zone types shown below...

Page 31: ...when ZONE NO appears on the display Choose NO to make changes to the alarm action for a zone ALARM ACTION Change the default alarm characteristics of a zone type If you selected the non 24 hour zone t...

Page 32: ...he receiver if bypass reports is set to YES CROSS ZONE Choose YES to enable cross zoning for this zone Cross zoning requires this zone to trip twice or this zone and another cross zoned zone to trip w...

Page 33: ...Code You can change this code at any time to any combination of numbers from 1 5 digits long 1 65535 Do not use leading zeros for the lockout code 1 Press any select area The keypad displays ENTER COD...

Page 34: ...eports are enabled in the Ademco Honeywell panel a duplicate message will also be sent to the central station Note Communicators with Version 194 and higher do not require you to log in to the VISTA p...

Page 35: ...P SETUP and press any select key or area 2 At ECP SETUP VISTA 128 If the panel is a VISTA 128 select YES If the panel is a different model select NO 3 At INST CODE enter the ECP panel installer code a...

Page 36: ...eypad buzzes END Press this select area to stop the walk test When the walk test ends or a 20 minute timeout expires a final sensor reset occurs The system test end message is sent to the receiver alo...

Page 37: ...owing a Program output 17 to turn on when armed Stay Output Funct Enter 01 Press to continue Summary Screen 01 A E P Trig Press to continue Activated by Enter 2 Press to continue Enter Zn Type Enter 2...

Page 38: ...HI HI HI LO LO LO LO HI HI LO LO HI HI LO LO HI TIP BROWN RING GRAY TIP GREEN RING RED BLACK RED SYNC COM DATA USE SA4120XM 1 CABLE 1 2 3 4 5 6 7 8 OUT 17 12 AUX GND OUT 18 VISTA 20P ONLY Ademco Vista...

Page 39: ...gital Monitoring Products 35 Bosch Control Panel Option Bus to CellCom LTE for Reduced Noise Disturbance Option Bus CellCom LTE V PROG 12 G Z1 Z2 Z4 Z4 G Z3 R T O2 O1 R B Control Panel R B G Y Figure...

Page 40: ...ed radio TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment If necessary the instal...

Page 41: ...hite 685 R Surface Mount Conduit Backbox red 383 Replacement Dual Band Cellular Antenna 330 DSC DSC Remote Programming Harness Compatibility ECP Passthru VISTA 15 VISTA 20 VISTA 21 VISTA 128 DSC Passt...

Reviews: