Programming (PROG) Connection
A 4‑pin programming header is provided to connect a keypad when using a DMP Model 330 programming cable.
This provides a quick and easy connection for programming the communicator. For 24 VDC applications using the
communicator, connect the keypad using a Model 330‑24 4‑wire programming harness with an in‑line resistor. After
programming is complete, remove the keypad.
Caution:
If connecting to a 24 VDC control panel, do not connect a keypad using a Model 330 harness.
Tamper
The tamper is pressed when the cover of the communicator is secured onto the enclosure. When the cover is
removed, the communicator sends a tamper trouble message to the central station.
Reset Button
The reset button is located on the upper right side of the circuit board and is used to reset the communicator. After
resetting the communicator, begin programming within 30 minutes. If you wait longer than 30 minutes, reset the
communicator again.
Note:
After the panel is reset, cell suppression is disabled for 30 minutes.
Load Button
Firmware can be updated with the programming header. Firmware updates are available for download, free of charge,
on the DMP Dealer Direct website at
Caution:
Do not connect a Model 401 to the communicator if using 24 V power.
Performing a Firmware Update
To update the communicator with a new firmware version, complete the following steps at the protected premise:
399 Programming Cable
1. Connect a DMP 399 Cable from the programming header to the serial port of your PC operating Remote Link
and containing the communicator RU file.
2. Start Remote Link and create or open the account that matches the communicator to be updated.
3. Set the connection information type to direct with a baud rate of
38400
and choose the appropriate COM port.
4. Select
Panel > Remote Update
, then select the correct RU file for the communicator.
5. Press and hold the load button, then press and release the reset button.
6. Release the load button and select
<Update>
in Remote Link.
7. After the firmware update is completed, remove the 399 cable and press the reset button to resume normal
operation.
Model 401 USB Flash Module
When loading the firmware RU file onto a USB drive, place the file in the root directory of the USB drive. The update
cannot be inside a folder. Format the USB drive as FAT32.
Place only one firmware file in the root directory. If more than one RU file exists on the USB drive, the communicator
will choose the RU file with the most recent date modified.
Caution
: DualCom, CellCom, iCom, and XTL+ do not use the same RU files. Using the wrong RU file for the update
will cause the communicator to stop working until the correct RU file is used to flash the firmware.
1. Connect the USB flash drive to the Model 401.
2. Press and hold the reset button on the communicator. You will continue to hold reset until step 6.
3. Connect the assembly to the communicator’s programming header.
4. Press and release the button on the Model 401.
5. With your finger still on RESET, press and hold the load button. Continue to hold LOAD until step 8.
6. Release the reset button.
7. Press and release the button on the Model 401.
8. When the green LED on the Model 401 starts a slow flash, release the load button. The slow flash will last
5 minutes, then the green LED will become steady, indicating the firmware version is updated.
Note:
If the LED blinks rapidly, the update was unsuccessful. Press and release RESET. Begin again at step 1
9. Press and hold RESET. Remove the Model 401, then release RESET to resume normal operation.
In the event the Model 401 USB Flash Module is inadvertently removed from the communicator before the update
finishes, repeat steps 1‑9.
Summary of Contents for CellCom LTE Series
Page 4: ......