Digital
Monitoring
Products
CellCom‑LTE Programming and Installation Guide
26
ZONE INFORMATION
This allows you to define the operation of each protection zone used in the system.
ZONE NUMBER
The communicator has four zones to program. Enter the number of the zone you intend to
program. To program zone 4, see Zones 1‑4 Input Connection. Press
CMD
to enter a zone
name. See Letters and Special Characters.
ZONE NAME
Press any select area and enter up to 16 characters for the zone name. A name must be
given to each zone in the system. The zone name is sent to the receiver as part of a zone
event report. A zone that is not part of the system must be marked *
UNUSED
*. To mark
a zone unused, de lete the old name by pressing any select area, then press
CMD
. The
programmer auto matically pro grams the name as *
UNUSED
*. If you selected
ZONES
NO
YES
to clear the communicator’s memory during initialization, the zones will already be
marked *
UNUSED
ZONE TYPE
The zone type defines the response of the communicator to the zone being open or short.
When you assign a zone type to a zone, responses are made automatically for the zone.
There are 12 zone types to choose from including Blank.
To select a new zone type, press any select area. The display lists the four zone types
shown below. When the zone type you want to select displays, press the select area below
or on the name.
Blank (
--
), Night (
NT
), Day (
DY
), or Exit (
EX
). Press
CMD
to display additional zone types.
Fire (
FI
), Panic (
PN
), Emergency (
EM
), or Supervisory (
SV
). Press
CMD
to display additional
zone types.
Auxiliary 1 (
A1
), Auxiliary 2 (
A2
), Arming (
AR
), or Fire Verify (
FV
). Press the back arrow to
display the previous zone types.
If you select Blank, Night, Day, Exit, Auxiliary 1, or Auxiliary 2 as the zone type, the zone
must be assigned to an area. See Zone 1‑4 Input Connection. If you select Fire, Panic,
Emergency, or Supervisory as the zone type, these are 24‑hour zones that are always
armed and no area assignment is needed.
Area Assignment
All non‑24‑hour zones are automatically assigned to area 1. Enter the area number from 1‑6
where this zone is being assigned.
Arming Zone Assignment
Specify the areas to be armed by the arming type zone. Press the appropriate numbers on
the keypad to assign areas 1‑6. When disarmed, all areas are disarmed.
ZONE INFORMATION
ZONE NO: ‑
* UNUSED *
ZONE TYPE: BLANK
A1 A2 AR FV
FI PN EM SV
‑‑ NT DY EX
AREA NO: 1
AREA: 1 ‑ ‑ ‑ ‑ ‑
Summary of Contents for CellCom LTE Series