ECP Passthru
Program Vista Keypad Device Address 20
1. Power down and then power up the Honeywell panel.
2. Within 1 minute of powering up the Honeywell panel, simultaneously press and hold the
#
and
*
buttons on the
keypad.
3. The keypad displays
INSTALLER CODE
. Enter the installer code (default is
4112
), followed by
8 0 0
.
4. Enter
*193
, then enter
1 0
.
5. To save and exit programming, enter
*99
.
User Codes in the Ademco/Honeywell Panel
Because the communicator duplicates the panel’s user codes, existing user codes in the Ademco/Honeywell panel,
including master, must be added to the communicator. The DualCom must also have user 2 as a master using the
same user code as the host panel user 2. This is required to allow codes added via App/Browser to be sent to the host
panel. Any new user codes added to the communicator from the Virtual Keypad App will be automatically entered in
the Ademco/Honeywell panel.
User codes from the Ademco/Honeywell panel that are designated as master or partition master should be configured
as master codes in the communicator.
If the Ademco/Honeywell panel is armed/disarmed from a keypad, the communicator reports an opening/closing
message by user 0 to the central station.
When the communicator is armed by the Virtual Keypad App or VirtualKeypad.com, the Ademco/Honeywell panel
is also armed and the communicator reports an opening message. If opening and closing reports are enabled in the
Ademco/Honeywell panel, a duplicate message will also be sent to the central station.
Note:
Communicators with Version 194 and higher do not require you to log in to the VISTA panel with a master
code to manage user codes remotely.
Manually Configure Communication with the Ademco/Honeywell Panel
The following steps describe how to configure Ademco/Honeywell control panels to communicate with the
communicator. Only use these steps if programming isn’t configured automatically with
ECP SETUP
.
1. Program Position * 54: Enter 0. This enables no signaling delay.
2. Program Position * 55: Enter 1. This enables communication to the communicator.
3. Program Position * 84: Enter 0. This disables CP01 and allows remote Arm Away.
4. Program Position * 193: Enter 1 0. This enables the DualCom ECP Bus address.
If the Ademco/Honeywell panel fails to communicate with the communicator, program Position * 29 to enable the
long range radio on the Ademco/Honeywell panel.
DSC Passthru
Remote Programming
DSC panels allow a 6‑hour interval for remote programming connections after the panel is initially powered up.
After that interval expires, technicians can re‑enable DLS connection for another 6 hours by disarming the panel and
entering the following code combination:
*6
+ [
master cod
e] +
5
.
1. Right‑click Remote Link and select
Run as administrator
.
2. If necessary, create the communicator account.
3. Double‑click the communicator account.
4. Minimize Remote Link.
5. Open DLS.
6. Double‑click the DSC panel.
7. Edit programming as needed, then press the Upload Programming button.
False Alarm Reduction
System Recently Armed report
The system recently armed report (S78) is sent when a burglary zone goes into alarm within two minutes of the
system being armed.