background image

Digital

 

Monitoring

 

Products 

CellCom‑LTE Programming and Installation Guide

30

APPENDIX

This section provides additional zone and system information.

ECP Passthru 

Program Vista Keypad Device Address 20

1.  Power down and then power up the Honeywell panel.
2.  Within 1 minute of powering up the Honeywell panel, simultaneously press and hold the 

#

 and 

*

 buttons on the 

keypad.

3.  The keypad displays 

INSTALLER CODE

. Enter the installer code (default is 

4112

), followed by 

8 0 0

.

4.  Enter 

*193

, then enter 

1 0

.

5.  To save and exit programming, enter 

*99

.

User Codes in the Ademco/Honeywell Panel

Because the communicator duplicates the panel’s user codes, existing user codes in the Ademco/Honeywell panel, 

including master, must be added to the communicator. The DualCom must also have user 2 as a master using the 

same user code as the host panel user 2. This is required to allow codes added via App/Browser to be sent to the host 

panel. Any new user codes added to the communicator from the Virtual Keypad App will be automatically entered in 

the Ademco/Honeywell panel. 
User codes from the Ademco/Honeywell panel that are designated as master or partition master should be configured 

as master codes in the communicator.
If the Ademco/Honeywell panel is armed/disarmed from a keypad, the communicator reports an opening/closing 

message by user 0 to the central station.
When the communicator is armed by the Virtual Keypad App or VirtualKeypad.com, the Ademco/Honeywell panel 

is also armed and the communicator reports an opening message. If opening and closing reports are enabled in the 

Ademco/Honeywell panel, a duplicate message will also be sent to the central station.

Note: 

Communicators with Version 194 and higher do not require you to log in to the VISTA panel with a master 

code to manage user codes remotely.

Manually Configure Communication with the Ademco/Honeywell Panel

The following steps describe how to configure Ademco/Honeywell control panels to communicate with the 

communicator. Only use these steps if programming isn’t configured automatically with 

ECP SETUP

.

1.  Program Position * 54: Enter 0. This enables no signaling delay.
2.  Program Position * 55: Enter 1. This enables communication to the communicator.
3.  Program Position * 84: Enter 0. This disables CP01 and allows remote Arm Away.
4.  Program Position * 193: Enter 1 0. This enables the DualCom ECP Bus address.

If the Ademco/Honeywell panel fails to communicate with the communicator, program Position * 29 to enable the 

long range radio on the Ademco/Honeywell panel.

DSC Passthru

Remote Programming

DSC panels allow a 6‑hour interval for remote programming connections after the panel is initially powered up. 

After that interval expires, technicians can re‑enable DLS connection for another 6 hours by disarming the panel and 

entering the following code combination: 

*6

 + [

master cod

e] + 

5

.

1.  Right‑click Remote Link and select 

Run as administrator

.

2.  If necessary, create the communicator account.
3.  Double‑click the communicator account.
4.  Minimize Remote Link.
5.  Open DLS.
6.  Double‑click the DSC panel.
7.  Edit programming as needed, then press the Upload Programming button.

False Alarm Reduction

System Recently Armed report

The system recently armed report (S78) is sent when a burglary zone goes into alarm within two minutes of the 

system being armed.

Summary of Contents for CellCom LTE Series

Page 1: ...CellCom LTE V Series Communicator Digital Monitoring Products Inc 2020 PROGRAMMING AND INSTALLATION GUIDE...

Page 2: ...n 14 Programming 15 Before You Begin 15 Getting Started 15 Programming Menu 15 Reset Timeout 16 Special Keys 16 Letters and Special Characters 17 Current Programming 17 Initialization 18 Clear All Cod...

Page 3: ...Message To Transmit 27 Output Number 27 Output Action 28 Swinger Bypass 28 Cross Zone 28 Receiver Routing 28 Zone Number 28 Stop 29 Set Lockout Code 29 Stop 29 Set Lockout Code 29 Appendix 30 ECP Pass...

Page 4: ......

Page 5: ...COMPONENTS Terminals Power Connection Terminals The communicator may be powered from the 12 VDC or 24 VDC auxiliary output of the control panel Observe polarity and use 18 22 AWG wire to connect the c...

Page 6: ...tion information type to direct with a baud rate of 38400 and choose the appropriate COM port 4 Select Panel Remote Update then select the correct RU file for the communicator 5 Press and hold the loa...

Page 7: ...IVITY OPERATION Green Steady Communicator Disarmed Primary Power OK No Light No Power Red Steady Communicator Armed Primary Power OK ECP and DSC Passthru Perform an ECP or DSC Passthru and communicate...

Page 8: ...place to protect the communicator from damage due to tampering or the elements It is not necessary to remove the PCB when installing the communicator Figure 1 System Components DC Z1 Z2 Z3 G T R Z4 O1...

Page 9: ...nnect the Antenna Place the antenna onto the SMA connector Refer back to Figure 1 Twist the antenna until it is securely tightened Replace the housing cover on the mounted base Be sure to not damage a...

Page 10: ...y Use a normally closed output on a burglary control panel to indicate a burglary alarm The communicator zone should be programmed with a zone name and burglary zone type When the output on the contro...

Page 11: ...adence type zone number and type of message sent to the receiver The communicator generates zones 5 and 6 using the zone name of zone 4 to send to the central station Zones 5 and 6 cannot be preprogra...

Page 12: ...O1 O2 Use 18 22 AWG for Power Supply connection 1k Z4 DMP Panel 12 VDC Aux Output ADEMCO Panel 12 VDC Aux Output BELL 12 VDC BELL NAPCO Panel 12VDC Aux Output BELL 12 VDC BELL DSC Panel 12 24 VDC Aux...

Page 13: ...n about configuring ECP Passthru refer to COM Series How To Guide ECP Passthru LT 2209 PROG B R RESET LOAD DC Z1 Z2 Z3 G T R Z4 O1 O2 DualCom 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2...

Page 14: ...on 2 0 or higher VISTA 15 Yes No No No No VISTA 15P Yes Yes Yes Yes Firmware version 5 2 or higher VISTA 20SE Rev 12 or higher No No No No VISTA 20P Yes Yes Yes Yes Firmware version 5 2 or higer VISTA...

Page 15: ...nnection Model 330 DSC PC LINK 1 CON 4 YELLOW GREEN YELLOW GREEN TAB UP Figure 9 DSC Passthru Wiring COMMUNICATOR TO DSC WIRING Communicator Terminal DSC Terminal DC RED DC BLK Z4 YEL Z4 GRN T or T1 T...

Page 16: ...tput or remote arming output in output options when programming the communicator See Armed Output or Remote Arming Output The communicator output connections can be used with any of the applications l...

Page 17: ...minal 23 on the control panel 4 Connect the R ring terminal on the communicator to terminal 24 on the control panel 5 Power the communicator by connecting its terminal 12V to terminal 5 on the control...

Page 18: ...o the panel Press Yes 13 Configure additional options as needed then press Save Tech APP Activation 1 Go to the Customer Summary Systems 2 Tap the Add icon 3 Enter the System Name 4 In System Type sel...

Page 19: ...ed or deleted in panel programming To revert the default code to 99 use the Clear All Codes option found in the Initialization menu Panels ship with the master code on the serial number label in paren...

Page 20: ...ress CMD to advance to the next step CMD is also used to enter information into the communicator s memory such as an IP address or a zone name Press CMD after entering information Back Arrow Use the b...

Page 21: ...er character or press CMD if finished NUMBER SELECT KEY 1 SELECT KEY 2 SELECT KEY 3 SELECT KEY 4 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 P Q R 7 S T U 8 V W X 9 Y Z space _ 0 Standard Keyboard Press...

Page 22: ...NG Choose NO to leave existing zone information intact Choose YES to set all zones in the system to UNUSED CLEAR COMMUNICATION Choose NO to leave existing communication programming intact Choose YES t...

Page 23: ...ly if this option is used FAIL TIME MINUTES Fail time allows the SCS 1R or SCS VR receivers to miss a defined number of check ins before logging that the panel is missing For example if cell check in...

Page 24: ...the receiver The default is NO Supervisory Trouble Reports Choose YES to enable Supervisory Trouble Trouble Restoral Force Armed Late to Close and Fault reports to be sent to this receiver Choose NO...

Page 25: ...remotely The default is YES Choose NO to disable remote disarming REMOTE OPTIONS RMT KEY DISARM NO YES SYSTEM REPORTS This option allows you to select which reports the communicator sends to the rece...

Page 26: ...zone time can be from 4 250 seconds in one second increments Enter 0 to disable the cross zone time feature See Cross Zoning POWER FAIL DELAY Enter the time allowed for a power failure to occur befor...

Page 27: ...to enable communication between the communicator and an Ademco Honeywell panel using the Z4 terminals Using the Ademco Honeywell ECP Bus the communicator can add delete and change user codes as well a...

Page 28: ...e can be 1 15 minutes Enter 0 to provide continuous output Note The output is cutoff within 60 seconds of the programmed cutoff time The cutoff timer is shared by all outputs If a second output trips...

Page 29: ...bad zones If a closing report is sent the user number is indicated as SCH on the SCS 1R or SCS VR receivers Choose NO to disable automatic arming for this area The default is NO Bad Zones At the time...

Page 30: ...e responses are made automatically for the zone There are 12 zone types to choose from including Blank To select a new zone type press any select area The display lists the four zone types shown below...

Page 31: ...when ZONE NO appears on the display Choose NO to make changes to the alarm action for a zone ALARM ACTION Change the default alarm characteristics of a zone type If you selected the non 24 hour zone t...

Page 32: ...he receiver if bypass reports is set to YES CROSS ZONE Choose YES to enable cross zoning for this zone Cross zoning requires this zone to trip twice or this zone and another cross zoned zone to trip w...

Page 33: ...Code You can change this code at any time to any combination of numbers from 1 5 digits long 1 65535 Do not use leading zeros for the lockout code 1 Press any select area The keypad displays ENTER COD...

Page 34: ...eports are enabled in the Ademco Honeywell panel a duplicate message will also be sent to the central station Note Communicators with Version 194 and higher do not require you to log in to the VISTA p...

Page 35: ...P SETUP and press any select key or area 2 At ECP SETUP VISTA 128 If the panel is a VISTA 128 select YES If the panel is a different model select NO 3 At INST CODE enter the ECP panel installer code a...

Page 36: ...eypad buzzes END Press this select area to stop the walk test When the walk test ends or a 20 minute timeout expires a final sensor reset occurs The system test end message is sent to the receiver alo...

Page 37: ...owing a Program output 17 to turn on when armed Stay Output Funct Enter 01 Press to continue Summary Screen 01 A E P Trig Press to continue Activated by Enter 2 Press to continue Enter Zn Type Enter 2...

Page 38: ...HI HI HI LO LO LO LO HI HI LO LO HI HI LO LO HI TIP BROWN RING GRAY TIP GREEN RING RED BLACK RED SYNC COM DATA USE SA4120XM 1 CABLE 1 2 3 4 5 6 7 8 OUT 17 12 AUX GND OUT 18 VISTA 20P ONLY Ademco Vista...

Page 39: ...gital Monitoring Products 35 Bosch Control Panel Option Bus to CellCom LTE for Reduced Noise Disturbance Option Bus CellCom LTE V PROG 12 G Z1 Z2 Z4 Z4 G Z3 R T O2 O1 R B Control Panel R B G Y Figure...

Page 40: ...ed radio TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment If necessary the instal...

Page 41: ...hite 685 R Surface Mount Conduit Backbox red 383 Replacement Dual Band Cellular Antenna 330 DSC DSC Remote Programming Harness Compatibility ECP Passthru VISTA 15 VISTA 20 VISTA 21 VISTA 128 DSC Passt...

Reviews: