Digital
Monitoring
Products
CellCom‑LTE Programming and Installation Guide
28
OUTPUT ACTION
Enter an output number to display this option. This option allows you to assign an output
action to the output. A description of the available output actions follows:
STD
(steady): The output is turned on and remains on until the area is disarmed, an output
cutoff time expires, or the output is reset from the keypad user menu.
PLS
(pulse): The output alternates one second on, one second off until the area is
disarmed, an output cutoff time expires, or the output is reset from the keypad user menu.
MOM
(momentary): The output is turned on only once for one second.
FLW
(follow): The output is turned on and remains on while the zone is in off, normal, or
bad condition. When the zone restores, the output is turned off.
After you have selected the message to transmit, the display prompts you for the same
three selections for Disarmed Short, Armed Open, and Armed Short conditions. If the zone
is a 24‑hour type, only the Armed Open and Armed Short conditions are displayed. When
you have programmed all of the zone conditions, the panel displays the swinger bypass
selection.
SWINGER BYPASS
Choose
YES
to allow the zone to be swinger bypassed by the communicator according to
the programming in swinger bypass trips and reset swinger bypass.
Choose
NO
to disable swinger bypassing for this zone.
How it works
If within one hour, a zone trips the total number of times as specified in swinger bypass
trips, the communicator bypasses it until the following conditions occur:
• The area in which the zone is assigned is disarmed.
• The zone is manually reset through the bypass zones keypad user menu function.
• The zone remains normal for one hour and reset swinger bypass is set to
YES
.
If the zone trips fewer than the specified times within one hour of the first trip, the bypass
trip counter returns to 0 and the process must be repeated. A report of the swinger bypass
is sent to the receiver if bypass reports is set to
YES
.
CROSS ZONE
Choose
YES
to enable cross zoning for this zone. Cross zoning requires this zone to trip
twice, or this zone and another cross‑zoned zone to trip, within a programmed time before
an alarm report is sent to the receiver. To operate correctly, all cross‑zoned zones need to
be programmed as the same zone type.
When a cross‑zoned zone trips, the output action assigned to the zone activates. The
cross zone time specified in system options begins to count down. See Cross Zone Time. If
another cross‑zoned zone in the system faults, or if the first zone restores and faults again
before the cross zone time expires, the bell turns on and the communicator sends an alarm
report.
If no other cross‑zoned zone in the system trips before the cross zone time expires, the
communicator sends only a fault report from the first zone to the receiver. If cross zone is
set to yes, a valid cross zone time must be programmed for this feature.
Choose
NO
to disable cross zoning for this zone. The default is
NO
.
RECEIVER ROUTING
This option displays if zone type is set for Auxiliary 1 or Auxiliary 2. Press any select area to
select the receiver routing for the selected zone.
Select
NORM
to send alarm and supervisory/trouble messages from this zone to receiver 1
or receiver 2 as programmed within the receiver in communications.
Select 1 to send alarm and supervisory/trouble messages from this zone to receiver 1 only,
regardless of the programming for the receiver in communications.
Select 2 to send alarm and supervisory/trouble from this zone to receiver 2 only, regardless
of the programming for that receiver in communications.
Select
BOTH
to send alarm and supervisory/trouble from this zone to both receivers,
regardless of the programming for either receiver in communications.
ZONE NUMBER
Enter the zone number you want to program next. Return to Zone Information and follow
the descriptions of each programming option. If all zones are programmed, press the back
arrow at the
ZONE
NO
display to continue.
ACTION:
STD PLS MOM
FLW
SWGR BYP NO
YES
CRS ZONE
NO
YES
RECEIVER ROUTING
NORMAL
NORM 1 2 BOTH
ZONE NO: ‑