47
COMPLIANCE LISTING SPECIFICATIONS
UL Access Control
The access relay must be configured as fail‑safe or fail‑secure as determined by the local
Authority Having Jurisdiction (AHJ). This system is not intended to be used in place of
listed panic hardware.
For listed installations, the 734N or 734N‑POE must be installed within the protected
area.
The power supply must be a listed commercial burglary/household fire, power limited,
Class 2 with a compatible voltage range for the product. The 734N requires a 12 or
24 VDC power source. The 734N‑POE can be powered by a 12 or 24 VDC or UL 294
listed POE switch.
For UL Access and Commercial Burglary, the 734N‑POE must be installed inside a UL
listed DMP metal enclosure such as a Model 341. Refer to Mount the Device for mounting
instructions.
POE power to be supplied by a UL 294 Listed, power limited, injector providing
44‑57 VDC and 15.40 W for maximum output (POE).
POE power to be supplied by a UL 294 Listed, power limited, injector providing
50‑57 VDC and 30.0 W for maximum output (POE+).
POE power to be supplied by a UL 294 Listed POE+ Midspan or Endspan providing
44‑57 VDC and 30 W for maximum output.