16
734N Series Installation and Programming Guide | Digital Monitoring Products, Inc.
OSDP Reader LED Operation
OSDP readers connected to 734N Series modules provide visual indication of relay
condition, connection type, and encryption status with a red and green LED. Enable
reader LED operation in
LED CONTROL
.
If enabled, the reader LED is turned on and operates the same as a Wiegand reader LED,
lighting green when the module relay activates. Visual indication for connection and
encryption status functions as follows:
•
Fast blink (50 ms interval)
—Connection secure, encrypted with 128‑bit AES and
your custom secure key.
•
Slow blink (100 ms interval)
—Connection encrypted with the default SIA secure
key.
•
None
—Connected, but not secure or encrypted.
If disabled, the reader LED is turned off and does not operate in any condition.
OSDP Reader Annunciation
OSDP readers connected to 734N Series modules provide audible indication of card
reads. Enable reader annunciation in
BUZZER CONTROL
.
If enabled, the reader’s internal annunciator follows normal RA terminal operation.
If disabled, the reader’s internal annunciator will beep once when a credential is
presented.