6.3.8 RUN-Menu
The RUN-Menu is used for manual activation of the FlexxPump 125. A special dona-
tion from FlexxPump 125 can be triggered in this way. This function can, for example,
be used for the advantageous "Quick Check" to manually check the condition of the
lubrication point.
FlexxPump 125 carries out a special donation after triggering the RUN function. Depen-
ding on the set operating mode, the FlexxPump 125 executes either one or as many
strokes in succession as set in the number of strokes (c) in the PRO menu. During the
stroke, the back pressure detected by the integrated microelectronics is displayed in
the LCD as an approximate value in bar.
There is no fault or error at FlexxPump 125.
Remove the activation and programming key from the bottom of FlexxPump 125 and
place it on the action area.
Hold the activation and programming key on the action surface. The yellow LED lights
up. Leave the activation and programming key on the action area until RUN is display-
ed in the LCD. Remove the activation and programming key from the action area as
long as RUN is displayed in the LCD. The yellow LED disappears.
Ü
The LCD flashes together with the green LED twice. The FlexxPump 125 starts deli
-
vering the lubricant to the outlet (special donation or "Quick-Check").
Insert the activation and programming key into the hole provided on the underside of
the FlexxPump 125 or repeat the special dispenser ("Quick-Check") if necessary.
Observe the back pressure values displayed on the LCD if they are of interest to
you.
During the dispensing process, the green LED lights up; in addition, the counterpres-
sure for the stroke is displayed in the LCD.