revision: 0
FlexxPump 125 (24V)
User Manual
13
EN-
SCHMIERSYSTEME
D I R E C T L U B R I C A T I O N S Y S T E M S
D L S
3.4
Technical data
Housing
Dimensions without cartridge
83 x 82 x 85 (B x H x T)
mm
Dimensions with 125ml cartridge
83 x 152 x 85 (B x H x T)
Dimensions with 250ml cartridge
83 x 175 x 85 (B x H x T)
Weight (without cartridge)
ca.
350
g
Mounting options
backside: female thread M5 (2x)
bottom: female thread M5 (1x)
bottom: male thread M16 (1x)
max. torque mounting
3
Nm
Mounting position
any, upright (preffered)
Material housing
PA 6.6 GF30 / POM
Material outlet
stainless steel
Operating temperature
-15 ... +60
°C
Lubricant and hydraulics
Volume cartridge
125 or 250
cm³
Lubricant characteristics
grease until NLGI class 2
Number of outlets
1
Hydraulic connection
directly or via PA-tube
Number of lubrication points
up to 8 in conjunction with aluminum progressi-
ve distributor*
max. pressure
50 (-10%/+15%)
bar
Grease delivery
per stroke
0,15
cm³
Electrics
Display
LCD
Operating voltage (DC)
24 (
20V...28V
)
V
Protection
0,75 (slow blow)
A
Protection class
IP 54
Current consumption
I
max
< 0,3 I
quiescent
< 0,025
A
* The stated value depends on the specific application and may vary considerably in individual
cases depending on the lubricant used and other conditions.