3. Remove the protective cap from the bot-
tom of the FlexxPump 125.
Unscrew the yellow protective cap coun-
terclockwise from the bottom of the lubricant
outlet of the FlexxPump 125.
Remove the black protective cap from the
electrical M12x1 interface.
4. Connect the electrical interface
Connect the FlexxPump 125 to the exter-
nal power supply or controller via the M12x1
interface on the side of the FlexxPump 125
using a suitable connecting cable.
Depending on the application, both
connection cables with straight or angled
sockets can be used.
Please refer to chapter 7.1 or chapter
8.1 for the condition of the connection cable.
LCD
DANGER
Defective or faulty electrical connections or unauthorized live
components can lead to serious injuries or even death.
§
Have all electrical connection work carried out by qualified
personnel only.
§
Replace damaged cables or plugs immediately.
§
Before carrying out any electrical installation work, observe the
five safety rules of electrical engineering:
- Unlocking
- Secure against unintentional restarting.
- Check that there is no voltage.
- Ground and short-circuit.
- Cover adjacent live parts.