revision: 0
FlexxPump 125 (24V)
User Manual
20
EN-
SCHMIERSYSTEME
D I R E C T L U B R I C A T I O N S Y S T E M S
D L S
6.2
Factory settings
FlexxPump 125 is always delivered ex works with the following settings:
operating mode Hour-Mode -h-
Mode
OFF
FlexxPump 125 is switched off
The factory settings foresee using the FlexxPump 125 in the
Hour-Mode -h-
. If you
want to operate the FlexxPump 125 in
Empty-Time-Mode Et
or
Pulse-Control-Mo-
de PUL
, you have to make changes in the SET-Menu of the FlexxPump 125, chapter
6.3.7.
6.2.1 Default settings operating mode Hour-Mode -h-
Dispensing time
h = 6
The dispensing time is 6 hours.
Number of cycles
c = 1
The number of cycles is one (1) stroke
during
the
dispensing
time.
The default settings in the Hour-Mode result in an emptying time (service life) of 195
days (= 6.4 months) for a full 125 ml lubricant cartridge, provided that the FlexxPump
125 is permanently switched on and no special dispensations have been made. Within
approx. 6 hours, the FlexxPump 125 will deliver one donation per stroke (0.16 cm³).
Verify that the default settings are appropriate for your application and that the lubri-
cation point is supplied with the correct amount of lubricant per time unit.
If this is the case, you can operate the FlexxPump 125 with the default settings in the
Hour-Mode -h-.
If this is
not
the case, change the values for the dispensing time t and number of cycles
c accordingly; see chapter 6.3.9 for an explanation of how to make these changes.
To use FlexxPump 125, it must first be properly mounted and installed and then
switched on. Installation is very simple and described in detail in chapter 5.2; switching
on is described in chapter 6.3.3.
If you order a special version of FlexxPump 125 from the factory, the information
contained in the supplement is authoritative for you!