10.3.
Environment controller settings
The program
MPCCOM
has been developed for use in DOS. It does
not work under
Windows XP or any other Windows operating system
.
The MPCCOM program is started from DOS.
Using different parameters you can adjust the following settings:
•
Display the current version of your environment controller software as well as
statistical, configuration and control functions (temperature, ignition and so on).
•
Change the shutdown and delay time.
•
Change the reaction time of the power button on the unit’s front panel.
•
Set how the front panel power button is to be interpreted.
•
Set whether the DLoG MPC 6 is to constantly monitor the ignition signal during
operation.
Operation
Launching
MPPCOM.EXE -h
generates the following messages:
MPCCOM -d time0 set power-key time
(time0=time to wait before keypress is
recognized in 100ms
valid values [1..255])
MPCCOM -h show this help
MPCCOM -info, -i readout a lot of info stored in EEPROM
MPCCOM -p value set power-key mode
(0=power-key completely disabled
1=wait for the power-key to startup &
use the power-key to switch off the
device
2=ignore the power-key at startup & use
the power-key to switch off the device
3=wait for the power-key to startup &
ignore the power-key on the working
device
MPCCOM -t time1 time2 ...set timer values in sec
(valid values [1..65535])
(time1 = delay time,
time2 = switchoff time)