![DLoG MPC 6 Manual Download Page 45](http://html.mh-extra.com/html/dlog/mpc-6/mpc-6_manual_2512975045.webp)
Device
description
DLoG MPC 6
Manual
29
Relative humidity
10% to 90% at 40° C, non-condensating
In accordance with EN 60068-2-3
Mechanical
vibration
and shock-
resistance
Class 5M3 according to EN 60721-3-5: 1998 (land vehicles), 5 hrs
with 3.6 g effective noise and 36 vibrations with 30 g peaks or US
highway truck according to MIL-STD 810F: 2000 (Department of
Defense), 3 hrs with 1 g effective noise and 600 vibrations with 20
g peaks in operation, with Flash disk
3.6.13.
Test marks
CE
EN 55022 Class B
EN 55024, EN 61000-3-2, EN61000-3-3, EN 61000-6-2
IEC 60950-1, EN 60950-1, UL 60950-1
EN 300328-1 and EN 301489-17, in case DLoG data transmission
devices operating in the 2.4 GHz spectrum have been installed