Important
safety
notices
DLoG MPC 6
Manual
9
Device seal
The face of the DLoG MPC 6 device has a protective seal glued into its frame. Do not
attempt to remove the seal from the face, as this will cause irreversible damage to the
seal and render it unusable.
Before closing the device, ensure the seal is seated properly between the face and the
device housing – especially for devices compliant with protection class IP65.
Visually check the seal for defects (tears, cuts) and foreign bodies (dirt). If you can tell
the seal is damaged, or if you think it may be damaged, contact DLoG’s technical
service.
Replacing the seal on IP65 devices
Never replace the glued-in seal on devices compliant with protection class IP65
yourself. This will instantly void all present and future guarantees and liability claims
even during the agreed warranty period.
Closing the device
The front is attached to the base unit with hexagonal screws (M5 x 20 with an inside
diameter of 3 mm). These screws must be retightened with a torque wrench in all
devices.
Retighten all the hexagonal screws in a
cross-wise
pattern to the following torque:
DLoG MPC 6/110: 3 Nm
DLoG MPC 6/112: 4 Nm
Tighten both screws in the temporary cap and antenna cap with a torque wrench to a
torque of 1 Nm.
Please be aware that any licenses or guarantees may lose their validity if the device
has been improperly operated or opened/closed. For devices compliant with protection
class IP65, DLoG can no longer guarantee the safety rating if the device has been, for
example, improperly opened or closed by unqualified personnel.