22
After the first item is programmed, the
display will change to “END”. Press the item
selection corresponding to the last item in
the block. This option may transcend more
than one shelf, i.e. A1 to B9. Important
Note: Any column number ending in the
number “0” (ie A0, B0, C0, D0, E0) is not
included in STS blocks. Example: A1
through B6 will not include A0. Also, if you
use any column “0” for the end of a STS
block, it will include all shelves and columns
below it as the “0” columns are tied to the F
tray port on the control board. Example:
STS block A1 through B0 will actually
include A1 through E0, but does not include
A0.
In all of the above options, after a selection is
made, an audible tone will be heard and the
display will change briefly to “OK” then back to
“START”. Press “CLR” at any time to return to
SETUP MODE 2.
DEFAULT STS CONFIG -
Press key “D”
Configures the Space-to-Sales to the preset
mappings.
Press “D” on the keypad and the display will scroll
“DEFAULT STS CONFIG”. Press the “*” key to
configure Space-to-Sales in preset blocks of three
(A1 – A3, A4-A6, A7-A9, B1-B3,…).
DISPLAY STS CONFIG -
Press key “E”
Allows verification of the Space-to-Sales settings for
an individual item.
Press the letter “E” on the keypad. The display will
scroll “DISPLAY STS CONFIG”. Press the “*” key
and the display will change to “ITEM”. Enter any
selection item and the display will read “##-## ##.
The first ## indicates the first column in the
selection’s block. The second ## indicates the last
column in the selection’s block. The last ##
indicates the column that the next vend will come
from in this Space-to-Sales block. For example,
entering “A2” might display “A1-A3 A1, indicating
that selection A2 is part of the block that spans
between A1 and A3 and that A1 selection is next in
line to be vended.
SET VEND LIMIT -
Key “F”
Not available in software revisions 030.81 and
higher.
If a Vend fails-either due to a vend error or no
product detected in the recovery unit- and the drop
sensor is enabled, the VMC will mark the column as
sold out. If the Space-to-Sales is enabled, the
product column will be removed form the Space-to-
Sales rotation and the VMC will attempt to vend from
the next column in the Space-to-Sales block. If the
vender is unable to vend any products from a
Space-to-Sales block, the customer’s credit will be
returned and the entire block will be marked as
“SOLD OUT”.
Press the “F” key on the keypad. The display will
scroll “SET VEND LIMIT”. Press the “*” key while
the display is
scrolling, or wait until the message
scrolls off. The display will read” LIMIT #”.
The
value # is the current vend limit which is applied to
each selection. When # is 0, no vend limits are
enforced. Enter the desired vend limit and press the
“*” key to accept this value or press the “CLR” key to
cancel changes and return to SETUP MODE 2.
HEALTH RECHECK ENABLED/DISABLED -
Press
key “1”
When enabled, after a “HEALTH TIME” error has
occurred, the vender will recheck the cooler
compartment temperature 3 times in 15-minute
intervals. If the temperature drops below 41
degrees, the “HEALTH TIME” error is cleared and
selections are re-enabled. If any recheck reads
above a previous reading, or if the temperature is
not below 41 degrees by the third recheck, the
“HEALTH TIME” error will remain and selections will
continue to be blocked.
Press the number “1” key. The display will scroll
“HEALTH RECHECK ENABLED” or “HEALTH
RECHECK DISABLED”. There are now 2 choices:
1. Press the “CLR” key to leave the Health
Recheck setting unchanged and return to
“SETUP MODE 2”
2.
Press the “*” key to toggle the state. The
display will scroll a new message indicating
the updated state.
This setting is inconsistent with
NAMA guidelines for health-
controlled venders.
SET RETRY LIMIT -
Press key “2”
This function provides the customer with an
additional opportunity (opportunities) to make a
selection after a failed vend. When a retry limit is
set, credit remains on the vender and the customer
may make additional selections until the retry limit is
reached at which point credit is returned.
Press the number “2” key. The display will scroll
“SET RETRY LIMIT”. Then the display will read
“LIMIT #”. The value # is the current retry limit which
is used after an initial failed vend. This means that a
retry limit of 3 will allow the user a total of 4
selections: the initial selection plus 3 retries. After
the limit is reached, credit is returned. To change
the limit #, when “LIMIT #” is displayed press the #
key(s) to enter the retry limit you desire to be set.
SOLD OUT ENABLED/DISABLED -
Press key “3”
Controls sold out detection by the drop sensor.
When enabled, a signal is sent to the VCU when the
Summary of Contents for DN 2145
Page 1: ......
Page 40: ...40 DN55 VENDER NON ENERGY STAR Beverage Max Diagram 9 Column ...
Page 41: ...41 DN55 ENERGY STAR VENDER Beverage Max Diagram 9 Column ...
Page 42: ...42 DN35 VENDER NON ENERGY STAR Beverage Max Diagram 6 Column ...
Page 43: ...43 DN35 ENERGY STAR VENDER Beverage Max Diagram 6 Column ...
Page 44: ...44 DN55 35 Compressor Wiring Diagram ...
Page 45: ...45 DN55 DN2145 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC NON ENERGY STAR FIGURE 3 ...
Page 46: ...46 DN55 2145 AC DISTRIBUTION BOX SCHEMATIC EXPORT FIGURE 4 ...
Page 47: ...47 DN35 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC NON ENERGY STAR FIGURE 5 ...
Page 48: ...48 DN55 35 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC ENERGY STAR FIGURE 6 ...
Page 50: ...50 ECC SYSTEM SCHEMATIC RIGHT SIDE MDB SAMPLE ...
Page 51: ...51 ECC SYSTEM SCHEMATIC LEFT SIDE SAMPLE ...
Page 52: ...52 ASSY AC BOX DOMESTIC ...
Page 53: ...53 ASSY AC BOX DOMESTIC T8 Electronic ...
Page 54: ...54 ASSY AC BOX CE GS EXPORT ...
Page 56: ...56 MACHINE FRONT VIEW 1 14 6 7 3 5 2 4A 4B 4C 13 10 11 15 8 ...
Page 58: ...58 MACHINE FRONT VIEW 2 7 14 3 13 2 1E 1C 11 1B 6 10 11 1G 4 17 ...
Page 60: ...60 CABINET DETAIL 14 3 9 12 3 1 2 7 8 8B 7 10 11 11 13 5 6 ...
Page 64: ...64 SERVICE DOOR 1 1 5 6 7 8 6F 6J 3 6A 7 ...
Page 66: ...66 SERVICE DOOR 2 15 6 5 4 1 2 6 17 20 8 19 21 9 11 12 4 14 18 ...
Page 68: ...68 SERVICE DOOR 3 12 17 2 20 7 5 13 19 14 15 11 4 10 9 8 ...
Page 70: ...70 TALL GATE TRAY DETAIL 1 8 9 8 13 15 15 14A 14C 14B 18 16 14B 12 ...
Page 75: ...75 EXPORT AC DISTRIBUTION BOX 220 VAC 4 ...
Page 77: ...77 REFRIGERATION UNIT DN 55 35 FIN TUBE CONDENSER 19 11 10 13 18 9 1 22 15 13 16 6 5 2 8 17 ...
Page 79: ...79 REFRIGERATION UNIT TECUMSEH DN 5500 DN 5400 DN 2145 ROLL UP CONDENSER ...
Page 82: ...82 HARNESSES 1 2 3 7 4A 6 4B 24 22 5A 5B 5C 9 10A ...
Page 85: ...85 SCREWS NUTS ...