21
health control. The display will change to
“ENABLED” then back to “ITEM”.
2. One tray.
Pressing the letter of the shelf
followed by the * key will set control for all
selections on that shelf. For example, to
control the A shelf push key “A” followed by
“*” key. The display will change to
“ENABLED” then back to “ITEM”.
3.
Single selection.
Press the desired
selection number or numbers corresponding
to the selections that require the health
control function. After each selection is
made the display will change to “ENABLED”
then back to “ITEM”.
Press the keypad buttons again and the display will
flash “DISABLED” and return to “ITEM”. Priority will
be given to the higher ranked method If one
selection on the A tray was set to ENABLE using
option 3 above and you wish to change the
remaining selections on that tray using option 2, the
Setting for the entire tray would take precedence.
Conversely, if the tray was set using option 2 first
followed by the single selection using option 3, the
setting for the remainder of the shelf would remain
and the new price for the single selection would
change to the new value. Press “CLR” to return to
“SETUP MODE”.
DROP SENSOR ENABLED/DISABLED -
Press key
“8”
(PASSWORD REQUIRED)
Allows Enabling or Disabling of drop sensor Credit
Guard function. When enabled, the customer will
retain credit for the amount deposited if a product
does not pass through the sensor beam in the
recovery unit. This state will allow three attempts to
vend a product before credit is lost. Both states will
prevent a vend if a product is in the recovery unit.
Press the number “8” on the keypad and “ENABLE
DROP SENSOR” or “DISABLE DROP SENSOR” will
scroll across the display. Pressing the “*” key will
switch the state. Note: When the display shows
enabled, the state is actually disabled. Press the
“CLR” key to return to “SETUP MODE”.
SET COOL TIME -
Key “9”
Allows the service technician to vary the time
duration of the cool down period from 0 to 255
minutes. If no time is entered here, and the SET
COOL DOWN feature is started, the time duration of
the cool down period will be 240 minutes (4 hours).
To set the cool down time press the letter “D” on the
keypad and the display will scroll “SET COOL
TIME”, and then change to “COOL 240”. Use the
keypad to enter the duration of the cool down period
that you wish to use. Press the “*” key to enter your
preferred time into memory. The display will read
“OK” momentarily and return to “SETUP MODE”.
ENTER NEW PASSWORD -
Press key “0”
(PASSWORD REQUIRED)
Allows the service technician to enter a personalized
password. IF YOU DECIDE TO CHANGE FROM
THE DEFAULT PASSWORD, PLEASE ENTER THE
NEW PASSWORD SLOWLY AND CAREFULLY!!!
Press the number “0” on the keypad and “ENTER
PASSWORD” will scroll across the display. Press
the “*” key and the display will read “PW”. Enter the
password, the display will read “OK” momentarily
then “NEW PW” will be displayed. Enter the new
password. After the fourth character of the new
Password is entered the display will read “OK”
momentarily and return to “SETUP MODE”.
SETUP MODE 2
Enter SETUP MODE 2 by opening the main door
and pushing the Service button four times. The
display will read “SETUP MODE 2”
NEXT ITEM -
Press key “A”
SPACE TO SALES ENABLE/DISABLE -
Press key
“B”
Allows enabling or disabling the Space-to-Sales
vend mode. When Enabled, Space-to-Sales vends
are performed according to the configurations
defined using “DEFAULT STS CONFIG” and/or
“CUSTOM STS CONFIG”.
Press the Letter “B” on the keypad. The display will
scroll the current state of the Space-to Sales vend
mode as “STS ENABLED” OR “STS DISABLED”.
There are now two choices:
1. Press the “CLR” key to leave the Space-to-
Sales vend mode unchanged and return to
“SETUP MODE 2”
2. Press the “*” key to toggle the state. The
display will scroll a new message indicating
the updated state.
CUSTOM STS CONFIG -
Press key “C”
Configures the Space-to-Sales according to user
input.
Press the letter “C” on the keypad. The display will
read “START”. There are now 3 choices:
1. Pressing the “*” key will set STS to a one to
one configuration such that each selection is
mapped only to it’s corresponding column.
Note: This setting overrides any
previously defined Space-to-Sales
blocks
.
2. Pressing a tray selection followed by “*” will
configure an entire tray as a single Space-
to-Sales block. Example is selections A1
through A9 vend from columns A1 through
A9 sequentially.
3. Pressing an item selection (A1) will specify
the first product of the Space-to-Sales block.
Summary of Contents for DN 2145
Page 1: ......
Page 40: ...40 DN55 VENDER NON ENERGY STAR Beverage Max Diagram 9 Column ...
Page 41: ...41 DN55 ENERGY STAR VENDER Beverage Max Diagram 9 Column ...
Page 42: ...42 DN35 VENDER NON ENERGY STAR Beverage Max Diagram 6 Column ...
Page 43: ...43 DN35 ENERGY STAR VENDER Beverage Max Diagram 6 Column ...
Page 44: ...44 DN55 35 Compressor Wiring Diagram ...
Page 45: ...45 DN55 DN2145 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC NON ENERGY STAR FIGURE 3 ...
Page 46: ...46 DN55 2145 AC DISTRIBUTION BOX SCHEMATIC EXPORT FIGURE 4 ...
Page 47: ...47 DN35 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC NON ENERGY STAR FIGURE 5 ...
Page 48: ...48 DN55 35 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC ENERGY STAR FIGURE 6 ...
Page 50: ...50 ECC SYSTEM SCHEMATIC RIGHT SIDE MDB SAMPLE ...
Page 51: ...51 ECC SYSTEM SCHEMATIC LEFT SIDE SAMPLE ...
Page 52: ...52 ASSY AC BOX DOMESTIC ...
Page 53: ...53 ASSY AC BOX DOMESTIC T8 Electronic ...
Page 54: ...54 ASSY AC BOX CE GS EXPORT ...
Page 56: ...56 MACHINE FRONT VIEW 1 14 6 7 3 5 2 4A 4B 4C 13 10 11 15 8 ...
Page 58: ...58 MACHINE FRONT VIEW 2 7 14 3 13 2 1E 1C 11 1B 6 10 11 1G 4 17 ...
Page 60: ...60 CABINET DETAIL 14 3 9 12 3 1 2 7 8 8B 7 10 11 11 13 5 6 ...
Page 64: ...64 SERVICE DOOR 1 1 5 6 7 8 6F 6J 3 6A 7 ...
Page 66: ...66 SERVICE DOOR 2 15 6 5 4 1 2 6 17 20 8 19 21 9 11 12 4 14 18 ...
Page 68: ...68 SERVICE DOOR 3 12 17 2 20 7 5 13 19 14 15 11 4 10 9 8 ...
Page 70: ...70 TALL GATE TRAY DETAIL 1 8 9 8 13 15 15 14A 14C 14B 18 16 14B 12 ...
Page 75: ...75 EXPORT AC DISTRIBUTION BOX 220 VAC 4 ...
Page 77: ...77 REFRIGERATION UNIT DN 55 35 FIN TUBE CONDENSER 19 11 10 13 18 9 1 22 15 13 16 6 5 2 8 17 ...
Page 79: ...79 REFRIGERATION UNIT TECUMSEH DN 5500 DN 5400 DN 2145 ROLL UP CONDENSER ...
Page 82: ...82 HARNESSES 1 2 3 7 4A 6 4B 24 22 5A 5B 5C 9 10A ...
Page 85: ...85 SCREWS NUTS ...