12
•
DO NOT press the “*” key when setting prices
for individual selections.
SET NOT AVAILABLE TIMES
Password protected. Before entering or changing this
setting you must enter the password if one has been
assigned. This mode allows up to 4 different time
periods that use of the machine may be restricted.
To set Not Available Times enter the “SETUP MODE”
by opening the service door and pressing the Service
Button 3 times. Press the number 3 key; the display
will scroll “SET NOT AVAILABLE TIME”. Press the “*”
key and the display will show ”SHUTDOWN”. Press
the “A” key and the display will show “BLOCK 1”
which allows selection set up. Press the “A” Key to
scroll through the 4 different time periods (Block 1, 2,
3, 4) that operation of the machine will be restricted.
Press the “*” key and the controller will begin
displaying selections currently belonging to block until
all have been displayed or the “*” key is pressed and
display will show “END LIST” then “ITEM”. There are
now three (3) choices:
1) ALL SELECTIONS. Press the “*” key and
all selections in the vender will be set for
not available.
2) ONE TRAY. Pressing the letter of the
shelf (tray) followed by the “*” key will set
control for all selections on that shelf.
3) SINGLE SELECTION. Press the desired
selection number or numbers
corresponding to the selections that
require the set not available times.
Press the key buttons again and the display will flash
“DISABLED” and return to “ITEM”. Priority will be
given to the higher ranked method If one selection on
the A tray was set to “ENABLE” using option 3 above
and you wish to change the remaining selections on
that tray using option 2, the Setting for the entire tray
would take precedence. Conversely, if the tray was
set using option 2 first followed by the single selection
using option 3, the setting for the remainder of the
shelf would remain and the new set not available
setting would take affect. If “DISABLED” the selection
will be blocked during the scheduled time period.
Press the “CLR” key will exit the selection setup &
start the schedule setup. “START TIME” will scroll on
display once and change to “HOUR 00”. Enter the
hour (00 – 23) and press the “*” key. The display will
read “MIN 00”. Enter the minutes (00 – 59) and press
the “*” key. “END TIME” will scroll on display once
and change to “HOUR 00”. Enter the hour (00 – 23)
and press the “*” key. The display will read “MIN 00”.
Enter the minutes (00 – 59) and press the “*” key.
“SUN N” (day) will show on the display. Press the “A”
Key to toggle to “SUN Y”. To change to the next day
press the “*” key and the display will read “MON N”.
Use the “A” key to scroll through the days. When the
desired day is displayed, press the “*” key to scroll to
the next day. Press the “CLR” key to move to
“BLOCK 2”.
POINTS TO REMEMBER:
•
Before setting Not Available times and days, it
is recommended you check the DATE/TIME
settings.
•
All times entered must be in 24 hour format.
Summary of Contents for DN 2145
Page 1: ......
Page 40: ...40 DN55 VENDER NON ENERGY STAR Beverage Max Diagram 9 Column ...
Page 41: ...41 DN55 ENERGY STAR VENDER Beverage Max Diagram 9 Column ...
Page 42: ...42 DN35 VENDER NON ENERGY STAR Beverage Max Diagram 6 Column ...
Page 43: ...43 DN35 ENERGY STAR VENDER Beverage Max Diagram 6 Column ...
Page 44: ...44 DN55 35 Compressor Wiring Diagram ...
Page 45: ...45 DN55 DN2145 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC NON ENERGY STAR FIGURE 3 ...
Page 46: ...46 DN55 2145 AC DISTRIBUTION BOX SCHEMATIC EXPORT FIGURE 4 ...
Page 47: ...47 DN35 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC NON ENERGY STAR FIGURE 5 ...
Page 48: ...48 DN55 35 AC DISTRIBUTION BOX SCHEMATIC DOMESTIC ENERGY STAR FIGURE 6 ...
Page 50: ...50 ECC SYSTEM SCHEMATIC RIGHT SIDE MDB SAMPLE ...
Page 51: ...51 ECC SYSTEM SCHEMATIC LEFT SIDE SAMPLE ...
Page 52: ...52 ASSY AC BOX DOMESTIC ...
Page 53: ...53 ASSY AC BOX DOMESTIC T8 Electronic ...
Page 54: ...54 ASSY AC BOX CE GS EXPORT ...
Page 56: ...56 MACHINE FRONT VIEW 1 14 6 7 3 5 2 4A 4B 4C 13 10 11 15 8 ...
Page 58: ...58 MACHINE FRONT VIEW 2 7 14 3 13 2 1E 1C 11 1B 6 10 11 1G 4 17 ...
Page 60: ...60 CABINET DETAIL 14 3 9 12 3 1 2 7 8 8B 7 10 11 11 13 5 6 ...
Page 64: ...64 SERVICE DOOR 1 1 5 6 7 8 6F 6J 3 6A 7 ...
Page 66: ...66 SERVICE DOOR 2 15 6 5 4 1 2 6 17 20 8 19 21 9 11 12 4 14 18 ...
Page 68: ...68 SERVICE DOOR 3 12 17 2 20 7 5 13 19 14 15 11 4 10 9 8 ...
Page 70: ...70 TALL GATE TRAY DETAIL 1 8 9 8 13 15 15 14A 14C 14B 18 16 14B 12 ...
Page 75: ...75 EXPORT AC DISTRIBUTION BOX 220 VAC 4 ...
Page 77: ...77 REFRIGERATION UNIT DN 55 35 FIN TUBE CONDENSER 19 11 10 13 18 9 1 22 15 13 16 6 5 2 8 17 ...
Page 79: ...79 REFRIGERATION UNIT TECUMSEH DN 5500 DN 5400 DN 2145 ROLL UP CONDENSER ...
Page 82: ...82 HARNESSES 1 2 3 7 4A 6 4B 24 22 5A 5B 5C 9 10A ...
Page 85: ...85 SCREWS NUTS ...