![Divus OPENDOOR Manual Download Page 45](http://html.mh-extra.com/html/divus/opendoor/opendoor_manual_2510942045.webp)
DIVUS OPENDOOR manual
45
For example from IP address 192.168.0.100 the door opener of OD-Sip Plus should be activated for 10 seconds
through remote control. The resulting UDP data is the following:
- BSREM
- C0A80064 (192 = “C0”, 168 = “A8”, 0 = “00”, 100 = “64” by converting decimal to hexadecimal).
- 00 (sequence number 0= „00“ as hexadecimal number)
- 1 (relay 1 door opener)
- 0A (duration of 10 seconds, converted in hexadecimal it will be „0A“ )
- 1234 (standard authentication „1234“)
The result is „BSREMC0A800640010A1234“ and the Checksum is calculated as follows:
The ASCII code value of each character must be summed:
B = 66
S = 83
R = 82
E = 69
M = 77
C = 67
0 = 48
A = 65
8 = 56
0 = 48
0 = 48
6 = 54
4 = 52
0 = 48
0 = 48
1 = 49
0 = 48
A = 65
1 = 49
2 = 50
3 = 51
4 = 52
-------------
Sum = 1275
Alternatively the OPENDOOR UDP Calculator can be used to calculate the UDP commands with Checksum in an
easy way; the OPENDOOR UDP calculator can be downloaded together with the documentation.
Then divide the sum through 256:
1275/256 = 4
Then calculate the rest of this division:
1275 – (4 x 256) = 251
This rest must be converted into a 2 byte hexadecimal number:
251 = FB
This 2 byte hexadecimal number is the Checksum and is added at the end of the UDP
data (behind the authentication password):
BSREMC0A800640010A1234FB
Summary of Contents for OPENDOOR
Page 1: ...DIVUS OPENDOOR manual 1 DIVUS OPENDOOR OPENDOOR manual Version 3 0 REV09 20160720 ...
Page 36: ...DIVUS OPENDOOR manual 36 DIAGRAM OF THE CALL CHAIN FUNCTION ...
Page 48: ...DIVUS OPENDOOR manual 48 2 5 TECHNICAL INFORMATION 2 5 1 DIMENSION ...
Page 58: ...DIVUS OPENDOOR manual 58 ...
Page 59: ...DIVUS OPENDOOR manual 59 ...
Page 68: ...DIVUS OPENDOOR manual 68 3 4 TECHNICAL INFORMATION 3 4 1 DIMENSION ...
Page 75: ...DIVUS OPENDOOR manual 75 DIMENSION 110 0 x 85 0 x 50 0 mm WEIGHT 150 g ...
Page 79: ...DIVUS OPENDOOR manual 79 5 3 2 DIMENSION ...
Page 80: ...DIVUS OPENDOOR manual 80 5 3 3 EXAMPLE FOR COVER CUT OUT ...
Page 86: ...DIVUS OPENDOOR manual 86 6 5 2 DIMENSION ...
Page 91: ...DIVUS OPENDOOR manual 91 7 4 2 DIMENSION ...
Page 96: ...DIVUS OPENDOOR manual 96 ...
Page 105: ...DIVUS OPENDOOR manual 105 10 APPENDIX 10 1 WIRING SCHEMES 10 1 1 EXAMPLE WITH OD SECURE ...
Page 106: ...DIVUS OPENDOOR manual 106 10 1 2 EXAMPLE WITHOUT OD SECURE ...
Page 107: ...DIVUS OPENDOOR manual 107 10 1 3 EXAMPLE WITHOUT OD SECURE WITH OD PUSH_LED ...
Page 110: ...DIVUS OPENDOOR manual 110 10 3 NOTES ...
Page 111: ...DIVUS OPENDOOR manual 111 ...