- 25 -
0DT828 28/10/2010
IMPUT
Command
Function
Description
1 2
N.O
Automatic closing
Permanently closing the contact enables automatic closing.
1 3
N.O
Opening
The closure of the contact activates an opening operation.
1 4
N.O
Closing
The closing manoeuvre starts when the contact is closed.
41 40
N.C
Reversal safety device
Opening the safety contact triggers a reversal of the movement (reopening) during a closing operation.
1 8
N.C
Reversal safety device
Opening the safety contact triggers a reversal of the movement (reopening) during a closing operation.
1 9
N.C
Stop
Opening the safety contact stops the current operation.
1 9
N.O
Non-pulse command
Permanently opening the safety contact enables the operation by non-pulse command
In this state, the opening (1-3/1-20) and closing (1-4) controls function only if held in the pressed position,
and the automation stops when the controls are released.
All safety switches, the step-by-step control and the automatic closing function are disabled.
1 20
Partial opening
The closing of the contact activates a partial opening operation of the duration set with the RP trimmer.
Once the automation stops, the partial opening control performs the opposite operation to the one
performed before stoppage.
0 11
N.C
Closure limit switch
The opening of the limit switch contact stops the closure operation.
0 12
N.C
Limit switch slowdown
The opening of the limit switch contact activates the slowdown in opening.
0 13
N.C
Opening limit switch
The opening of the limit switch contact stops the opening operation.
Button
LED
Starts the opening operation.
The green LED on indicates the presence of the 24 V=power supply.
Starts the partial opening operation.
Starts and stops the STOP operation.
the red LED on indicates that the STOP has been activated.
the fl ashing red LED indicates that the safety devices have been activated.
Starts the closing operation.
KEYBOARD
Output
Value
Description
1 +
0 -
24 V= / 0,5 A
Accessories power supply.
Power supply output for external accessories, including automation status lamp.
LAMP
230 V~ / 50 W
Flashing light (LAMP).
Activated during opening and closing operations.
-F +F
24 V= / 1,2 A
200V= / 0.3 A
Electric motor brake.
The output is active for the duration of both the opening and closing operation.
230 V~ / 6 A
Three-phase motor.
Connect the contact of the motor circuit breaker in series to the limit switch.
Note: if the direction of rotation of the motor is incorrect for the desired direction of movement, swap the
L2 and L3 phases.
U W V
M
3 ~
OUTPUTS
ON
SEGNALAZIONI
LED
On
DL1
(2) Automatic closing
DL2
(3) Opening
DL3
(4) Closing
DL4
(9) Stop
DL5
(20) Partial opening
DL6
(40) Safety edge
LED
On
DL7
Stop push button
DL8
(8) Closing Safety
DL9
(13) Opening limit switch
DL10
(12) Slowing down limit switch
DL11
(11) Closing limit switch
DL12
Flashing lamp
LED
On
DL13
Run OK
DL14
Fault
DL15
Autotest
DL16
Brake
DL17
Cycles counter
C
B
A
B
C
300
A
¾
Adjustment limit switch
1. Set the deceleration ramps to zero. (T5 - T6)
2. Calibrate limit switch (C) on the geared motor so that the door stops
approximately 200-300mm from the closure point respectively.
3. Calibrate limit switch (A), at the wished quote.
4. Calibrate slowdown limit switch (B) in such a way that it engages at
approximately ¾ of the opening stroke.
5. Calibrate the opening speeds using trimmer (T3) and closure (T4).
6. Calibrate the opening (T5) and closure (T6) trimmers of the deceleration
ramps in such a way as to cause stopping in the actual door open and
door closed positions.
EN