- 24 -
0DT828 28/10/2010
T2
T4
T6
T1
T3
T5
J1
1
ON
8A
g
G
8A
g
G
+F -F U V W
2A F
230 V
50/60 Hz
L
N
GND
CNT
M
230 V 3PH
DL
10
11
9
8
7
6
5
4
3
2
1
12
15
16
17
13
14
41 40 20 9
8
4
3
2
1
1
0 LAMP
1 11 12 13
ON
OFF
1 2 3 4
U24
J2
21
Switches
Description
OFF
ON
DIP 1
Enable adjustment through trimmer
Step-by-Step.
Opening.
DIP 2
Prefl ashing opening
Step-by-Step.
Step-by-Step.
DIP 3
Future Use
Do not use.
Do not use.
DIP 4
Future Use
Do not use.
Do not use.
J2
Brake power spply
200Vdc Brake
24 Vdc Brake
Trimmer
Description
T1
Setting automatic closing time. From 0 to 30 s.
T2
Partial opening adjustment. From 0 to 10 s.
T3
Adjust opening speed.
T4
Adjust closing speed.
T5
Adjust deceleration in opening.
T6
Adjust deceleration in closing.
SETTINGS
4.2 47E (INVERTER) ELECTRONIC CONTROL PANEL - CONNECTIONS
To create cablings use double insulated wires with a 1,5 mm
2
minimum diameter for power connections and
0,5 mm
2
for signal and safety connections, complying with the insulation characteristics required by the specifi c
installation.
0 s
30 s
0 s
30 s
0
MAX
0
MAX
0
MAX
0
MAX
J2
EN