- 19 -
0DT828 28/10/2010
SIGNALS
LED
On
Flashing
POWER
24 V= power supply.
/
SA
Indicates that at least one of the safety contacts is
open.
- Indicates the STOP operation activated by pushbutton panel PT4 (if present).
- If the SOFA1-SOFA2 device is installed, this indicates a safety test failure
(terminal 41).
- On power on, the LED fl ashes to indicate the number of operations
performed:
each rapid fl ash = 10000 operations
each slow fl ash = 100000 operations
IN
Activated at every command and adjustment to the
dip-switch and jumper.
/
11
Indicates that the 0-11 limit switch contact is open.
/
12
Indicates that the 0-12 limit switch contact is open.
/
17
Indicates that the 0-17 limit switch contact is open.
/
Button
LED
Starts the opening operation.
The green LED on indicates the presence of the 24 V=power supply.
Starts the partial opening operation.
Starts and stops the STOP operation.
the red LED on indicates that the STOP has been activated.
the fl ashing red LED indicates that the safety devices have been activated.
Starts the closing operation.
KEYBOARD
ON
Output
Value
Description
1 +
0 -
24 V= / 0,5 A
Accessories power supply.
Power supply output for external accessories, including automation status lamp.
0 14
24V= / 50 W
(2 A)
Flashing light (LAMPH).
Activated during opening and closing operations.
-LK +LK
24V= / 1,2 A
Electric motor brake.
With EO=ON, the output is active for the duration of both the opening and closing operation.
With EO=OFF, the output is only active with the motor idle. (Active brake).
400 V~ / 4 A
Three-phase motor.
Connect the contact of the motor circuit breaker in series to the limit switch.
Note: if the direction of rotation of the motor is incorrect for the desired direction of movement, swap the
U - W phases.
400 V~ / 4 A
Second speed
Three-phase motor.
Second speed.
Note: if the direction of rotation of the motor is incorrect for the desired direction of movement, swap the
Y - Z phases.
U W V
M
3 ~
OUTPUTS
Y
M
3 ~
Z
X
IMPUT
Command
Function
Description
1 2
N.O
Automatic closing
Permanently closing the contact enables automatic closing.
1 3
N.O
Opening
With DIP1=ON the closure of the contact activates an opening operation.
Step-by-step
With DIP1=OFF the closure of the contact activates an opening or closing operation in the following
sequence: open-stop-close-open.
Note: if automatic closing is enabled, the stop is not permanent but at a time that is set by the TC.
1 4
N.O
Closing
The closing manoeuvre starts when the contact is closed.
41 6
N.C
Safety stop
All operations are stopped and/or blocked when the contact is opened.
41 8
N.C
Reversal safety device
Opening the safety contact triggers a reversal of the movement (reopening) during a closing operation.
1 9
N.C
Stop
Opening the safety contact stops the current operation.
1 9
N.O
Non-pulse command
Permanently opening the safety contact enables the operation by non-pulse command.
In this state, the opening (1-3/1-20) and closing (1-4) controls function only if held in the pressed position,
and the automation stops when the controls are released.
All safety switches, the step-by-step control and the automatic closing function are disabled.
1 20
Partial opening
The closing of the contact activates a partial opening operation of the duration set with the RP trimmer.
Once the automation stops, the partial opening control performs the opposite operation to the one
performed before stoppage.
0 11
N.C
Closure limit switch
The opening of the limit switch contact stops the closure operation.
0 12
N.C
Opening limit switch
The opening of the limit switch contact stops the opening operation.
0 17
N.C
Limit switch slowdown
The opening of the limit switch contact activates the slowdown in opening
EN