Systems and Equipment - 156
JT100/JT100 All Terrain Operator’s Manual
Electric Strike System
Voltage Test
1.
Place voltage limiter on something insulated from ground and drilling unit (such as dry board or tire),
but near frame of drilling unit.
2.
Clip one lead to frame.
3.
Clip other lead to one voltage limiter mount.
4.
Move simulator switch to "voltage" and press test button.
5.
Watch screen and lights above display on strike system.
•
All lights should turn on.
•
Alarm and strobe should turn on.
•
Voltage "V" should show 90% or higher.
It is normal for simulator voltage levels to drift below strike level. When this happens, light in triangle should
go off and alarm and strobe should stop working. If the level drifts above strike level again, light, alarm, and
strobe should be turned on again.