Systems and Equipment - 154
JT100/JT100 All Terrain Operator’s Manual
Electric Strike System
Strobe light and alarm on
drilling unit do not work
during total test
Improper connections with
control module
Check connections and wiring
harness
Defective control module
Have control module checked or
replaced
dc518 POST AC I
code displays and
red ESID current
indicator icon shows on
machine display.
Improper connections with
control module
Check cable connections on control
module and current transformer
Defective current transformer
1.
Disconnect current transformer.
2.
Check for 20-40 ohms from pin 1
to pin 4, 20-40 ohms from pin 1 to
pin 2, and less than 1 ohm from
pin 2 to pin 4.
Defective current transformer
cable
1.
Disconnect cable from
transformer and control module.
2.
Check continuity of cable.
3.
If continuity is zero or cable is
damaged, replace.
Defective control module
Have control module checked or
replaced
dc517 POST AC V
code displays and
red ESID voltage
icon shows on machine
display.
Improper connection of voltage
limiter to ground stake
Check voltage limiter connection to
ground stake and verify that ground
stake is driven into the ground
Improper connections with
control module.
Check cable connection on control
module.
Defective voltage limiter
Have voltage limiter checked or
replaced
Defective control module
Have control module checked or
replaced
Problem
Possible cause
Possible solution
Summary of Contents for JT100
Page 1: ...JT100 JT100 All Terrain Tier 4 Issue 2 1 Original Instruction Operator s Manual 053 2814...
Page 105: ...Prepare 104 JT100 JT100 All Terrain Operator s Manual...
Page 247: ...Service 246 JT100 JT100 All Terrain Operator s Manual As Needed...
Page 255: ...Service Record 254 JT100 JT100 All Terrain Operator s Manual Service Performed Date Hours...
Page 258: ......
Page 259: ......