POWERED BY POWER PACK (OPTIONAL IN 120T)
Starting the power pack:
1. Open the engine's petrol cock HA.
2. Activate the key switch in the chassis control centre of the lift.
3. Depress the choke button S40 in the electric centre of the power pack, and start the
engine by turning the start switch S6.
4. Release the choke as soon as the engine starts.
To switch off the engine, turn the same turn switch to the opposite direction. There
are corresponding switches also in the platform control centre. After the start, the lift's
movements can be operated using the standard operating controls of the lift.
The operation of the power pack is impeded, while the mains current of 230 VAC is
connected. The power pack will not start, if the level of lubrication oil is low. The oil level is
monitored by a level switch.
DANGER
WARNING
CAUTION
NOTICE
If the battery is flat, start the power pack by pulling the starter grip, and at the same time,
keeping the button S37 depressed. After the start, keep the button depressed for a while in
order to recharge the battery a little so that the relays will remain active.
Keep the maximum engine revolutions, because in certain situations, the hydraulic system
will require almost all the power output available. Adjust the revolutions, using the lever HB.
When you stop using the combustion engine, close the fuel cock.
The fuel cock must be kept closed during towing and long-term storing of the
lift.
Summary of Contents for DINO 120T
Page 2: ......
Page 6: ...6 Operating instructions DINO 120T 120TB BLANK...
Page 11: ...11 2 2 REACH DIAGRAM...
Page 45: ...45 BLANK...
Page 50: ...50 Operating instructions DINO 120T 120TB NOTES...
Page 51: ...51 NOTES...
Page 55: ...55 7 2 LUBRICATION PLAN 5 8 6 10 6 7 13 4 2 1 11 3 9 12...
Page 61: ...61 BLANK...
Page 62: ...62 Operating instructions DINO 120T 120TB BLANK...
Page 64: ...64 Operating instructions DINO 120T 120TB NOTES...
Page 65: ...65 NOTES...