3590EKR, 3590EXP, 3590EXT, CPWE, CPWET series indicator
E-AF09_02_16.03_EN_U
75
SET POINT ON THE NET WEIGHT
By selecting this functioning mode, in the normal scale mode, the relay function on the NET weight is enabled; the entry of
the SET POINTS and the specifications are the same as the functioning mode on the gross weight.
GROSS WEIGHT AT ZERO
By selecting this functioning mode, in the normal scale mode, the relay function on the GROSS weight at 0 is enabled.
NET WEIGHT AT ZERO
By selecting this functioning mode, in the normal scale mode, the relay function on the NET weight at 0 is enabled.
INSTABILITY
By selecting this functioning mode, in the normal scale mode, the relay function on the unstable weight is enabled.
TOTALISATION
By selecting this functioning mode the output function is enabled when the totalisation has taken place; the output remains
enabled until the totalisation is restored; in other words, by the passing by zero of the net weight or by weight instability (see
F.mode >> rEACt
parameter of the TECHNICAL SET-UP,
TECH.MAN.REF.
).
SET POINT ON THE PARTIAL TOTAL
By selecting this functioning mode, in the normal scale mode, the relay function is enabled on the sum between the NET
weight on the scale and the accumulated net partial total; the entry of the SET POINTS and the specifications are the same
as the functioning mode on the gross weight.
SET POINT ON THE GENERAL TOTAL
By selecting this functioning mode, in the normal scale mode, the relay function is enabled on the sum between the NET
weight on the scale and the accumulated net general total; the entry of the SET POINTS and the specifications are the same
as the functioning mode on the gross weight.
SET POINT ON THE GRAND TOTAL
By selecting this functioning mode, in the normal scale mode, the relay function is enabled on the sum between the NET
weight on the scale and the accumulated net grand total; the entry of the SET POINTS and the specifications are the same
as the functioning mode on the gross weight.
SETPOINT ON THE NEGATIVE NET WEIGHT
Functioning with hysteresis
(
rL.iSt
“HYSTERESIS” parameter set as
iSt.on
)
By selecting this functioning mode the outputs function on the NEGATIVE NET weight is activated; one enters two
NEGATIVE SET POINTS for each output: a DISABLING one, which, when the NET weight is greater than it, disables the
appropriate output; an ENABLING one, which, when the NET weight is lower or equal than it, it enables the appropriate
output.
The entry and specifications are the same for the functioning mode on the gross weight.
OUT1 STATUS
ENABLED
DISABLED
S1.on
S1.Off
NET WEIGHT