3590EKR, 3590EXP, 3590EXT, CPWE, CPWET series indicator
E-AF09_02_16.03_EN_U
32
11.3.4 PRINTING
1)
Press the
F3
key to access the database.
2)
Press the
F5
key: the
LCD display shows “PRINT?”. Confirm with
ENTER
or press another key to cancel. Here one is
given suggestions on how to print the list of the memory storages:
-
By pressing the
0
key
all the memory storages in the database
are printed, each with:
MEMORY NR.
PLATE
DESCRIPTION
TARE
TOTAL INPUT WEIGHT
TOTAL OUTPUT WEIGHT
NET TOTAL
WEIGHS TOTAL
-
By pressing the
1
key,
just the memories which have been handled
will be printed, each with:
MEMORY NR.
PLATE
DESCRIPTION
TARE
TOTAL INPUT WEIGHT = net weight of the quantity which has entered in the factory (in other words the sum of the
net weights greater than zero [so with the input weight greater than the output weight],
of all the pairs and of the
single weighs carried out)
.
TOTAL OUTPUT WEIGHT = net weight of the quantity which has left the factory (in other words the sum of the net
weights less than zero [so with the input weight less than the output weight],
of all the pairs and of the single weighs
carried out)
.
NET TOTAL = the net of all transactions (TOTAL OUTPUT WEIGHT minus the TOTAL INPUT WEIGHT).
WEIGHS TOTAL = number of weigh pairs (input weigh with relative output weigh) and of all the single weighs carried
out.
3)
Restart from point 2) or press
C
to return to weighing.
11.3.5 SELECTION / DESELECTION
With no memory storage selected, the LCD display shows in the data section (see 5.4 section):
To
SELECT
the memory storage, one can proceed in two ways:
1)
Type the memory storage number and press
F3.
2)
Press the
F3
key to access the database.
Select the memory storage:
a.
by using the arrow keys
b.
by typing the storage number with the keyboard (the LCD display shows the first corresponding PLATE line)
c.
by searching the plate (see section 11.3.7)
3)
Press a direct key combined to the desired article, for example one can activate the vehicle 1 by pressing directly the F6
key; to do this one has to combine the function 304 to the desired key and insert a preamble value equal to the storage
number to select (see
<< F.KEYS >>
step,
TECH.MAN.REF.
).
In both cases, the LCD display shows in the data section (see 5.4 section):
At this point the memory storage will be linked to the weigh under way and will be printed if foreseen in the ticket.
CUS MAT VEH
CUS MAT VEH