Digitronic
Digital Cam Switch Unit
Automationsanlagen GmbH
CamCon DC50/51
7.4.5.6. The analog speed output
CamCon emitts a voltage (proportional to the speed) on
the first analog output (pin 2 at CamCon DC50), 0 to -10V
with a negative rotation direction and 0 to +10V with a
positive rotation direction, if the menu point
"Speed
Analog"
is set to
"yes"
.
The output voltage reaches its maximum of 10V, when the
100% value, described in chapter "7.4.3. The speed
adjustment", is surpassed.
You can deactivate this function by setting the menu point to
"no"
with keys
and
, and
confirming it with the
key.
Note:
At the time, there are no integrated analog outputs available for CamCon DC16 and
DC90. You can add analog outputs by connecting a CamCon DAC16 digital - analog -
converter module to the external interface of the CamCon.
Note:
To clear the integrated analog outputs please see chapter "7.5.3.3.1. Clearing the
integrated analog outputs" on page 72.
7.4.5.7. Configuration of the analog cams
With a CamCon cam controller you have the possibillity to
make an output of free programmable analog values
(cams) dependent on the position. You enter the number
of analog outputs in the menu point
"Analog cams"
, that
you want to program via the CamCon. In most cases, this
will also be the number of your analog hardware outputs.
Note:
If the menu point
"Speed Analog"
is set
to
"yes"
, the first analog output is used to
display the speed, and the number of possible analog outputs is decreased by one.
When you enter the number and press the
key, you
enter the input of the specific settings for the analog cams:
First you choose the number of the nalog output with keys
and
.
Press the
key to confirm the number and change the
display to the input of the display format.
Here you enter your desired format, as described in
chapter "5.8. Text input" on page 27. It is e.g. possible to
make the input in percent "####.##%" (standard), in
voltage "###.###V", in bar "#.###mbar" or in Ampere
"##.###mA". The double-crosses are just placeholders for
the real numerical values. The skaling of the input values
is done in menu points
"Minimum"
and
"Maximum"
.
,Version from: Aug. 04
Page: 61