Digitronic
Digital Cam Switch Unit
Automationsanlagen GmbH
CamCon DC50/51
When you confirm the format with the
, you enter the
input for the minimum value.
Note that CamCon always calculates with an accuracy of
16 Bit. The minimum value is the bit value 0 (e.g. -10V or
4mA) and the maximum value is the bit value 65535
(e.g.+10V or 20mA). The values should be entered
according to the purpose of the device. If e.g. an CamCon
DAC16/I module (current output) is connected to the
external display, the input can be made in milliampere, or the milliampere value corresponds to a
physical preassure - or speed, this value can also be entered in bar or meters per second (see values
in figure above).
Note:
The integrated analog outputs of the CamCon DC40, 50 and 115 all work with an
accuracy of 8 Bit. The output of the analog cam values is recalculated from 16 bit to 8
bit in this case.
After the minimum and maximum values have been confirmed with the
key, the com inputs in the
programming menu are restricted to the range between minimum and maximum and recalculated, if
necessary.
The output of the analog value can be stopped by setting an input to a specific value. For this purpose
enter the input number in the menu point
"Dis.inp."
(Disable Input), with which the analog value is set
to the
"Dis.val."
(Disable Value). The "Dis.value" must be within the range of minimum and maximum.
The "Dis.val." is automatically set as a default value, if no cam has been programmed on the analog
output.
When the "Dis.val." is confirmed you can activate ("yes") or deactivate ("no") the interpolation of the
analog value with the keys
and
in the menu point
"Interpol."
. If this value is set to "yes",
CamCon interpoles the programmed values from definition point to definition point.
Example:
without interpolation
with interpolation
-10V
+10V
0°
90°
180°
270°
360°
-10V
+10V
0°
90°
180°
270°
360°
By pressing the
key, the input of the interpolation is confirmed, and you move back to the selection
of the number of the analog oiutput. Here you can choose the number of the next analog output with
the keys
and
and proceed with the input of the values as before.
When the input is finished, you can leave the menu by pressing the
key.
For the input of the cam values please see chapter "7.3.17. Programming analog cams" on page 43.