© 2022 Digitrax, Inc.
www.digitrax.com
16
16
Option
Switch #
Effect on System operation
Factory
Default
OPSW 27
t =
Enable normal switch commands, a.k.a. the “Bushby bit”
t
c =
Disable normal
switch commands, a.k.a. the “Bushby bit” Allows
attached PC to handle switch control logic
OPSW 28
t =
Enable interrogate commands at power on
t
c =
Disable interrogate commands at power on
OPSW 29
c
= Disable Booster transponding
t
OPSW 31
t =
Normal route/switch output rate
t
c =
Fast route/switch output rate
OPSW 33
t =
Track power off at power on
c
c =
Allow track power to restore to prior state at power on
OPSW 34
t =
Disallow track to power up to run state, if set to run prior to power on
t
c =
Allow track to power up to run state, if set to run prior to power on
OPSW 35
t =
Enables Loco Reset Button
t
c =
Disables Loco Reset Button
OPSW 36*
c =
Clears all mobile decoder info & consists
t
OPSW 37*
c =
Clears all routes
t
OPSW 39*
c =
Clears all internal memory states, including OPSW 36 & 37.
t
OPSW 40*
c =
Clears all internal memory states and sets Voltage Trim to default.
Resets to factory default
t
OPSW 41
t =
Diagnostic click disabled
t
c =
Diagnostic click when valid LocoNet commands incoming & routes
being output
OPSW 42
t =
Enable 2 short beeps when loco address purged
t
c =
Disable 2 short beeps when loco address purged
OPSW 43
t =
Enable LocoNet update of command station’s track status
t
c =
Disable LocoNet update of command station’s track status
OPSW 44
t =
Maximum slots to 400
t
c =
Limit slots to 120
OPSW 45
t =
Enable reply for switch state request
t
c =
Disable reply for switch state request
Option Switch Tables