background image

© 2022 Digitrax, Inc. 

www.digitrax.com

 18

18

5.3  DT602 Reading and Editing   routes: 

Using a  DT602 (of at least 

IPL version 0.6 or later) plugged into LocoNet, press the; Menu>3>4 keys to enter the 

advanced graphics 

Route Editor

 menu.   

1. 

The “EDIT CS Route# :” screen at right will a

ppear.

2.  The LH encoder knob now selects a Route# and 

the RH encoder selects the black 

outlined

 Entry# 

to edit in the route.  

3.  Soft A key will toggle the entry from T to C direc-

tion choice. 

4.  Numeric keys will change the SW# in the outlined 

Entry position. “Add” soft key allows inserting 

another entry at current position and “Delete” will 

remove the current entry. The “SW test” soft key 

will send just the outlined switch# and direction to 

LocoNet to test a switch, or trigger a route.

5.  After editing a Route is complete 

be sure

 to press 

the “Save” soft key  to update this in  

non-volatile memory. 

6.  Press “X” to exit DT602 Route Editor.

7.  If 

any

 7 series Accessory device is on LocoNet 

during this Route edit, the DT602 will beep after about one second and also show 

“DS7x” routes at the D soft key position.  These are additional editable route choices 

above capability.

Note: If there is an error with the route the will beep 5 times when the route 

is triggered.

6.0   Booster Operations (OPS) Mode read-back 

 

As for 

sec-

tion 5.3

, with a DT602, press the; Menu>2>1 keys to enter OPS Mode programming for 

the 

currently selected active throttle address.

1.  The initial screen allows OPS mode  CV number 

setting or CV data read/write modify.  

2.  For this example, press the 5 then 8 keys to select 

CV#58, then press the CVDATA or B-softkey to 

change to the CV Read/Write screen, as at right.

3.  Press the READ or B-softkey to read back CV58 

for  

active decoder 03 on the tracks powered by the 

booster, or RA/RB terminals

.

4.  In this case the Ops Mode read is OK, and the 

result is the CV58 value shows 10 in GREEN. 

5.  If decoder 03 was a Digitrax SFX Sound decoder 

step 4 actually reads the Sound Volume CV. You 

can us the number keys to set a valid CV58 value 

and then press WRITE or A-softkey to change the 

decoder to this new volume value in CV58. This CV change is NOT on PA/PB track.

6.  For Ops Read success the must have  OPSW29=T, the decoder must be 

Transponding capable and enabled.  Additionally for reliable OPS read there should 

not be incompatible or noisy decoders on these RA/RB booster tracks.

7.  Detection of a transponder will provide its address in Zone 2047.

EDIT CS Route#:   

01  of 64

 

Entry# 

TOP of 16

0100

c

0224

t

Thrown

Add

Save

Delete

CS Routes: LH knob selects

SW test

CV Program Menu A:

 

CV Number:

    CV data:

0058

0010

Ops Loco adr: 0003

         

SWITCH

WRITE

READ

BACK

Summary of Contents for DCS240

Page 1: ...2404 Support helpdesk digitrax com www digitrax com Digitrax Manuals Instructions are updated periodically Please visit www digitrax com for the latest version of all manuals for available firmware up...

Page 2: ...am A and B terminals PA and PB 9 3 4 Program PROG Indicator 9 3 5 Ground GR Terminal 9 3 6 Rail B RB and Rail A RA Terminals 10 3 7 USB Connector 10 3 8 USB Indicator 10 3 9 TRACK STATUS Indicator 10...

Page 3: ...7 0 How the DCS240 Manages Addresses 19 7 1 Purging of addresses 19 8 0 Connecting the DCS240 to a Computer 19 8 1 Driver Installation 19 8 2 Hardware Installation 19 8 3 Software Installation 20 8 4...

Page 4: ...DCS240 Option Switch OPSW settings for CS operation customization Hardware EZ Routes button for simple route setup Automatic CS collision detection via LocoNet Layouts can have only one CS Continuous...

Page 5: ...USB ports This isolates layout wiring issues 2 Set the DCS240 s SCALE switch to the scale you are running N HO O G Use the lowest setting and DC input voltage that will run your layout 3 Set the MODE...

Page 6: ...ection and track control without requiring a known functioning decoder install NOTE These are DT602 instructions please refer to your specific throttle manual for similar steps to perform these tests...

Page 7: ...e 2mm DC jack or 8A if connected to the 8A terminals 3 If the PWR or NET leds flash quickly during this short test this indicates that the DC supply voltage collapses too low at the short circuit curr...

Page 8: ...tion 1 3 detail connecting an Isolated program track for Service mode CV programming 2 1 1 Service mode programming Service mode programming broadcasts a message to all decoder equipped locos that are...

Page 9: ...VDC Input Minimum Input 13 8 VDC It is recommended that when selecting a DC power supply the voltage should slightly exceed by about 1V the track voltage you plan to run your layout at However the DC...

Page 10: ...analog locomotive 3 10 LOCONET Jacks A B and C These jacks let you expand your Digitrax system by simply plugging LocoNet devices in to the system They can be used for throttles and other LocoNet dev...

Page 11: ...indicator will flash GREEN alternating with the PROG indicator flashing RED 2 Press the LOCO RESET button The unit will start beeping continuously 3 Select Address 00 on a throttle plugged in directly...

Page 12: ...t things depending on the DCS240 s current mode Sound Meaning Continuous short beeps In Voltage Trim Mode selection is in range 1 Short Beep Diagnostic Beep when OPSW41 c LocoNet commands incoming In...

Page 13: ...REEN Command Station Mode RED Booster Only Mode PWR flashing GREEN alternat ing with PROG flashing RED The DCS240 is in Options Switch Mode PWR flashing alternating GREEN RED once a second The DCS240...

Page 14: ...ettings instead of the accessory decoders usually turnouts on the layout 6 Key in the number of the OPSW to edit 7 Use the Closed or B softkey key to set the OPSW to Closed C or the Thrown or A softke...

Page 15: ...oco to 0 speed OPSW 17 t Automatic advanced decoder assisted FX consists are enabled t c Automatic advanced decoder assisted FX consists are disabled OPSW 18 t Normal DCS240 booster short circuit shut...

Page 16: ...ower on OPSW 35 t Enables Loco Reset Button t c Disables Loco Reset Button OPSW 36 c Clears all mobile decoder info consists t OPSW 37 c Clears all routes t OPSW 39 c Clears all internal memory states...

Page 17: ...CS240 Route OPSW s By default the DCS240 is set route enabled OPSW 26 enables and disables routes To disable routes set OPSW 26 to T You can erase all current routes in the DCS240 by setting OPSW 37 t...

Page 18: ...e route is triggered 6 0 DCS240 Booster Operations OPS Mode read back As for sec tion 5 3 with a DT602 press the Menu 2 1 keys to enter OPS Mode programming for the currently selected active throttle...

Page 19: ...provides all the same functionality as a PR3 PR4 DCS210 and DCS52 giving you access to Digitrax SoundLoader and other computer utility programs It can also be used as a LocoNet interface for other com...

Page 20: ...r Under Ports COM LPT there should be a new Communications Port COMx listed when enumeration occurs where COMx is the communications port number or COM port Right clicking on this communications port...

Page 21: ...ssly approved by Digitrax voids the user s authority to operate under and be in compliance with CFR 47 rules as administered by the Federal Communication Commission Digitrax believes any consci entiou...

Page 22: ...fitness for a particular purpose For items that are no longer covered under warranty whenever possible we will make repairs to units at fair and reasonable rates Please visit our warranty and repair...

Page 23: ...2022 Digitrax Inc www digitrax com 23 23 page intentionally blank...

Page 24: ...er will fit in a particular locomotive Digitrax CV Calculators www digitrax com support cv Calculate a CV value to program your locomotive Digitrax Tool Box App Download our Mobile App for on the go h...

Reviews: