background image

© 2022 Digitrax, Inc. 

www.digitrax.com

7

7

problem before proceeding. 

7.  If the PROG led 

does not flash after you press the READ key

, the program track has 

a stray voltage or isolation problem, and you will have to power cycle the  

after 

you fix this program track issue.

8.  Now move the two test track wires over to the RA/RB main track terminals.  Make 

sure the TRK STATUS led is lit, so the locomotive is energized.

9.  On the DT602, for the active throttle press the Loco and the detected active AD2 or 

AD4 address number from steps 4 or 5 earlier. Press the Loco key again to complete 

decoder address selection.

10.  Ensure that as you increase the now active throttle speed the locomotive responds in 

both directions by movement on the track.

11.  At this point you have proven the will operate properly and you can now 

install this on your layout.

1.4  Layout hookup test:

 

These steps will introduce the to an existing 

layout.

1.  Before connecting the RA/RB terminals to the layout, perform a 

short-circuit detection test.  With TRACK STATUS lit/ON, short these two termi-

nals or connected wires together.  The should beep 4 times and turn OFF 

the track for about 1 second, then briefly pulse on the led to show it is attempting to 

restart track power.  

2.  If the does not shut down reliably, check that the DC supply is rated for 

5A if connected via the 2mm DC jack, or 8A if connected to the 8A+/- terminals.

3. 

If the PWR or NET leds flash quickly during this short test, this indicates that the 

DC supply voltage collapses too low at the short circuit current draw, so a better DC 

supply is required to properly operate.

4.  If the Short circuit test is OK, you can now connect the RA/RB terminals to your 

layout, and check you can now run the locomotive from 

section 1.3

 step 10, OK on 

the mainline tracks.

5.  Now you can connect the layout LocoNet connection to a RJ12 port on this  

CS.  If the NET led remains lit red, you can connect the DT602 to a loconet jack 

around the layout and check it will again operate the test locomotive OK.

6. 

As you operate the test locomotive the NET led will flash indication loconet control 

messages are being received.  If the NET led stays off, the  loconet has short prob

-

lem in the layout cabling.

7.  You can now hook up an isolated program track and test it works as for 

section 1.3

.

8.  If your detects two command stations on the LocoNet at power up, it will 

issue 10 long beeps and turn off all track power.

1.5  Shutting Down the System

When you are finished with your session, you can shut down the  by turning 

off power to the system, but this may fail to save some just-modified data. Some users 

prefer to “dispatch” or release all addresses active in their system before shutting down.  

This can prevent unexpected results when you power up the layout again.  

You can sim

-

ply press the Loco Reset Button on the  to clear all addresses from the com

-

mand station at the end of a session.

Summary of Contents for DCS240

Page 1: ...2404 Support helpdesk digitrax com www digitrax com Digitrax Manuals Instructions are updated periodically Please visit www digitrax com for the latest version of all manuals for available firmware up...

Page 2: ...am A and B terminals PA and PB 9 3 4 Program PROG Indicator 9 3 5 Ground GR Terminal 9 3 6 Rail B RB and Rail A RA Terminals 10 3 7 USB Connector 10 3 8 USB Indicator 10 3 9 TRACK STATUS Indicator 10...

Page 3: ...7 0 How the DCS240 Manages Addresses 19 7 1 Purging of addresses 19 8 0 Connecting the DCS240 to a Computer 19 8 1 Driver Installation 19 8 2 Hardware Installation 19 8 3 Software Installation 20 8 4...

Page 4: ...DCS240 Option Switch OPSW settings for CS operation customization Hardware EZ Routes button for simple route setup Automatic CS collision detection via LocoNet Layouts can have only one CS Continuous...

Page 5: ...USB ports This isolates layout wiring issues 2 Set the DCS240 s SCALE switch to the scale you are running N HO O G Use the lowest setting and DC input voltage that will run your layout 3 Set the MODE...

Page 6: ...ection and track control without requiring a known functioning decoder install NOTE These are DT602 instructions please refer to your specific throttle manual for similar steps to perform these tests...

Page 7: ...e 2mm DC jack or 8A if connected to the 8A terminals 3 If the PWR or NET leds flash quickly during this short test this indicates that the DC supply voltage collapses too low at the short circuit curr...

Page 8: ...tion 1 3 detail connecting an Isolated program track for Service mode CV programming 2 1 1 Service mode programming Service mode programming broadcasts a message to all decoder equipped locos that are...

Page 9: ...VDC Input Minimum Input 13 8 VDC It is recommended that when selecting a DC power supply the voltage should slightly exceed by about 1V the track voltage you plan to run your layout at However the DC...

Page 10: ...analog locomotive 3 10 LOCONET Jacks A B and C These jacks let you expand your Digitrax system by simply plugging LocoNet devices in to the system They can be used for throttles and other LocoNet dev...

Page 11: ...indicator will flash GREEN alternating with the PROG indicator flashing RED 2 Press the LOCO RESET button The unit will start beeping continuously 3 Select Address 00 on a throttle plugged in directly...

Page 12: ...t things depending on the DCS240 s current mode Sound Meaning Continuous short beeps In Voltage Trim Mode selection is in range 1 Short Beep Diagnostic Beep when OPSW41 c LocoNet commands incoming In...

Page 13: ...REEN Command Station Mode RED Booster Only Mode PWR flashing GREEN alternat ing with PROG flashing RED The DCS240 is in Options Switch Mode PWR flashing alternating GREEN RED once a second The DCS240...

Page 14: ...ettings instead of the accessory decoders usually turnouts on the layout 6 Key in the number of the OPSW to edit 7 Use the Closed or B softkey key to set the OPSW to Closed C or the Thrown or A softke...

Page 15: ...oco to 0 speed OPSW 17 t Automatic advanced decoder assisted FX consists are enabled t c Automatic advanced decoder assisted FX consists are disabled OPSW 18 t Normal DCS240 booster short circuit shut...

Page 16: ...ower on OPSW 35 t Enables Loco Reset Button t c Disables Loco Reset Button OPSW 36 c Clears all mobile decoder info consists t OPSW 37 c Clears all routes t OPSW 39 c Clears all internal memory states...

Page 17: ...CS240 Route OPSW s By default the DCS240 is set route enabled OPSW 26 enables and disables routes To disable routes set OPSW 26 to T You can erase all current routes in the DCS240 by setting OPSW 37 t...

Page 18: ...e route is triggered 6 0 DCS240 Booster Operations OPS Mode read back As for sec tion 5 3 with a DT602 press the Menu 2 1 keys to enter OPS Mode programming for the currently selected active throttle...

Page 19: ...provides all the same functionality as a PR3 PR4 DCS210 and DCS52 giving you access to Digitrax SoundLoader and other computer utility programs It can also be used as a LocoNet interface for other com...

Page 20: ...r Under Ports COM LPT there should be a new Communications Port COMx listed when enumeration occurs where COMx is the communications port number or COM port Right clicking on this communications port...

Page 21: ...ssly approved by Digitrax voids the user s authority to operate under and be in compliance with CFR 47 rules as administered by the Federal Communication Commission Digitrax believes any consci entiou...

Page 22: ...fitness for a particular purpose For items that are no longer covered under warranty whenever possible we will make repairs to units at fair and reasonable rates Please visit our warranty and repair...

Page 23: ...2022 Digitrax Inc www digitrax com 23 23 page intentionally blank...

Page 24: ...er will fit in a particular locomotive Digitrax CV Calculators www digitrax com support cv Calculate a CV value to program your locomotive Digitrax Tool Box App Download our Mobile App for on the go h...

Reviews: