SEED COUNT
This function counts the number of seeds passing through each seed
sensor. This function is selected by pressing the OPERATE 3 switch until
the COUNT message appears.
Press the START STOP RESET switch to start the measurement, then
press it again to stop. The ON and OFF messages on the display indicate
the Seed Count function status. To zero the accumulated seed count on
the selected row, press and hold the START STOP RESET switch until a
beep occurs (approximately one (1) second). To zero the seed count for all
rows, press and hold the START STOP RESET switch for at least three (3)
seconds. When a total of 99999 counts is exceeded, the count rolls over to
zero (0). Press the SELECT ROW switch to advance the display to the next
row. Press the BACK switch to return to the previous row.
Any other Operate Mode function can be selected while Seed Count is
running without affecting the actual seed counts. (
Figure 62
) shows a
stopped seed counter with 1693 seeds counted on row fourteen (14).
Figure 62
Seed Count Display
DISTANCE ACCUMULATOR
Distance Accumulator measures distances in feet (meters) with 0.1
resolution. It can only be used after the Distance Calibration Constant has
been accurately established (See the SETUP MODE section for details).
This function is selected by pressing the OPERATE 3 switch until the
DISTANCE and ACC messages appear on the display.
Press the START STOP RESET switch to start the measurement then
press it again to stop. The ON and OFF messages on the display indicate
the Distance Accumulator function status. To zero the distance
accumulator, press and hold the START STOP RESET switch until a beep
occurs (approximately one (1) second). When a total of 9999.9 feet
(meters) is exceeded the accumulator rolls over to zero (0).
Any other Operate Mode function can be selected while Distance
Accumulator is running without affecting the actual distance accumulation.
(
Figure 63
) shows a running distance accumulator with 783.6 feet
measured.
Summary of Contents for seed manager
Page 4: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 2 SAFETY NOTICES...
Page 6: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 4 INTRODUCTION...
Page 22: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 20 INSTALLATION AND SETUP...
Page 46: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 44 STARTUP...
Page 64: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 62 SELF TEST ERROR CODES...
Page 70: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 68 SELF TEST ERROR CODES...