OPERATOR’S MANUAL
Seed Manager SE
11001-1359A-200810
STARTUP / 41
19. POPULATION SCALING FACTOR
The population scaling factor allows fine adjustments to be made in the
readout of population and spacing on a percentage basis. This value is
adjustable from 1% to 999% with the factory default being 100%. Use the
SET and SELECT switches to adjust to the desired population scaling
factor. (
Figure 46
) shows a Population Scalar of 105%.
NOTE: Use (
Figure 16
) Setup Mode
Parameters as reference for the
following items numbered 1-21
Figure 46
Population Scaling Display
20. SENSOR/MODULE SELF-TEST
Start the test by pressing the START STOP RESET switch. The TEST
message flashes while the test is executing (Note: This is the same test
that is performed automatically during console power up). When the test is
complete the display will show either PASSED (and scroll through all
available seed rows) or show FAILED and display the appropriate error
code(s). If multiple errors exist, the E in the error code will be flashing. To
view the next error code, press the Alarm switch. (
Figure 47
) shows the
Sensor/Module Self Test screen.
NOTE: For a full description of all the
error codes and their meanings,
see the ERROR CODES
section.
Figure 47
Sensor Self Test Display
Summary of Contents for seed manager
Page 4: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 2 SAFETY NOTICES...
Page 6: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 4 INTRODUCTION...
Page 22: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 20 INSTALLATION AND SETUP...
Page 46: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 44 STARTUP...
Page 64: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 62 SELF TEST ERROR CODES...
Page 70: ...OPERATOR S MANUAL Seed Manager SE 11001 1359A 200810 68 SELF TEST ERROR CODES...