6. Service
6.1. General
All maintenance activities must happen at an
disconnected machine
and
hoses without pressure
.
Checking the electric components can happen exclusively by an expert.
Exclusively accessories and replacement components which have been approved by the manufacturer can be
used. Directly after the activities all securities- and protection parts must be assembled, before the machine is put
into functioning.
“a golden rule” that contributes to a perfectly working machine with few problems, is well the following:
A DAILY CONTROL AND CLEANING OF THE MACHINE FREQUENTLY DO WONDERS!
To be able to guarantee a perfectly working system, one has first necessary a reliable and technical well consid-
ered machine, which is then faced secondly at regular times with a thorough maintenance. Therefore the experi-
ence and the “know-how” of DiBO a technical good working machine is insured and large maintenance turns
can be carried out by experienced DiBO technicians by means of appointment or maintenance contract, we can
suppose in advance that it is satisfied to these two points.
6.2. Maintenance diagram
6.2.1 General
The user can carry out only those actions for which in this book authorisation are given.
Each other act has been prohibited!
For the maintenance turns of burner kettle, high pressure pump, combustion engines and of components
which have to do with the security, one must contact our DiBO technicians.
Open the hood (cap) only for service purposes (example: at engine) using the 2 star buttons (see photo) at the
bottom and at the front of the machine.
6.2.2. Periodic maintenance
- Control of the electric cables, high and low pressure hoses
and coupling and control of the oil level.
After each use.
- Refreshing pump oil.
First 50 hours.
-
Refreshing
reduction gearbox oil.
First 50 hours.
- Cleaning water filter.
Each 50 hours/each month.
- All following refreshments of pump oil / reduction gearbox oil.
Each 400 hours/yearly.
- Maintenance engine (oil replace).
- Clean air filter/exhaust. Replace oil filter/spark plug(s).
- See also added motor manual for all other maintenance items
which need to happen.
First 5 hours & next 50 hours.
Yearly.
Pay attention, shorter maintenance
intervention necessary to the motor!
- Extra control/replacement of joints, valves, o- rings by ac-
knowledged DiBO- technicians!
Each 600 hours.
6.2.3. Control/refreshing of oil level and pump oil
Check for each use of the machine the oil with the oil level glass or with the oil level bar.
Oil must stand right with the sign of the oil level glass, if the this case is not, oil tops up until the sign.
If oil looks forward to there milky, consult directly the DiBO technicians. To refresh oil, as follows work goes:
- Unbolt the drain plug below the pump.
- Unbolt the tap with the oil level bar.
- Catch all oil in a barge and remove oil like further described in the guide.
- Force up the drain plug there and top up the oil in the breach to the upper part to on the mark line.
- Force up the tap with the oil level bar there.
- Recommended oil: 1.836.042.