11. Frame
The frame is made of a powder coated steel construction.
The frame has cut- outs below the machine to transport easily (by forklift).
Below the frame, a plate is mounted at the frame (side in front) to service easliy (electric box).
12. Alternator
The alternator serves to generate a tension (12 V) for power supply of the electric parts.
13. Safety valve
When the water pressure increases above the preset safety pressure, the safety valve opens and the water flows
pressureless below the cleaner.
14. Flow switch
As soon as there is sprayed, water flows through the flow switch.
The switch controls if there is a flow of water. At sufficient flow the burner can function.
15. Burner
The type of burner depends on the type of cleaner. The ‘green burner’ is a burner that makes a higher efficiency.
The burner provides hot water. The temperature of the water is adjustable. The burner is double- walled.
The outside wall is air cooled by the ventilator lateral on the burner chamber. On top of the burner one can find
the burner mouth. The water supply and outlet are both situated at the bottom of the burner.
Lime scale deposits while working at higher temperatures
The hardness of the water is possible expressed in French degrees (°F) or German degrees (°D).
The difference is noticeable in the following equation: 1 ° F = 0.56 ° D.
For example, water having a hardness of 40 ° F has a German hardness of 40 x 0.56 = 22.4 ° D.
See the in your area prescribed hardness of drinking water.
Hard water can cause problems by means of lime scale from 30°F or 17°D.
When hardened water is now warmed / heated / or being pumped (or when hard water comes in contact with air),
this can cause calcification. Hard water is caused mainly by the presence of two components: calcium and magne-
sium. So the harder the water, the more chances on lime scale! When cleaning with high temperatures (or at using
heated water) , you obtain thus faster calcification in case of a low hardness!
This can therefore result in loss of energy efficiency, higher energy consumption and reduced capacity of water
supply (including calcium deposits on the burner coil and other water connection parts).
We, DIBO NV, therefore recommend to decalcify the machines with a burner preventive additionally and after use
of hot water rinse adequate with cold water (if possible) to ensure optimum performance of the machine!
Summary of Contents for JMB-E
Page 2: ...JMB E REV 0 DiBO n v 2 ...
Page 111: ...JMB E REV 0 DiBO n v 111 11 Technical data ...
Page 115: ...JMB E REV 0 DiBO n v 115 ...