USER´S MANUAL
49-M500WMEN25
150
18.2. WORKING MODES OF THE 500 SERIES BATTERY
Depending on whether the scale is connected to the electricity supply source or not, regardless of whether
it is switched on or not, or during operation, the scale is in one of the following states:
‘0’ – cable disconnected, with the scale switched off: it is not being charged.
‘1’ - cable connected, with the scale switched off: it is being charged
‘2’ - cable disconnected, with the scale switched on: battery fed, it is being used up.
‘3’ - cable connected, with the scale switched on: mains supply, it is being charged.
18.3. BATTERY CONTROL PARAMETERS
The 500 RANGE battery models offer a parameter (BATTERY CONTROL) which allows you to select
consumption mode in which the battery will operate.
There are three possible values for this parameter:
0: Operation with no saving in consumption.
1: Operation with average savings in consumption. (default value)..
2: Operation with maximum savings in consumption.
Please contact your DIBAL dealer to know the procedure for programming this parameter.
18.4. OPERATION DEPENDING ON THE BATTERY CONTROL PARAMETER
VALUE
18.4.1.Battery control to 0
There is no saving in battery. The scale consumes the same as a scale operating without batteries.
18.4.2.Battery control to 1(default value)
There is average saving in battery.
The Backlight operates in timer mode, with a NON-MODIFIABLE timing of 10 seconds, in such a way
that, if there are no variations in the weight on the tray or in key pressing in this period of time, the
backlight switches off.
The RS-232 and USB Interfaces deactivate their power supply circuits. There is no serial
communication.
18.4.3.Battery control to 2
There is maximum savings in battery life.
The Backlight switches off and cannot switch itself on.
The Ethernet Controller disables itself and there are no Ethernet connections or communication to
M/S or PC.
The RS-232 and USB Interfaces disable their power supply circuits. There is no serial
communication.