500 Range
49-M500WMEN25
103
PROG 7.4.1.4
10
LABEL WAY OUT
PROG 7.4.1.5
1
TYPE OF PAPER
PROG 7.4.1.6
21
FOR. TOTAL L 1
PROG 7.4.1.7
0
FOR. TOTAL L 2
PROG 7.4.1.8
15
FOR. TOTAL L 3
11.4.1.4.Heading [ 7 4 1 4 ]
This parameter affects the printing mode of both the labels
and the receipts, and can have a value of between 0 and 1
with the meanings:
‘0’ -
No backward and does not print the header.
‘1’ - Backward and prints the header.
Enter the required value as a number from 0 to 1.
Press
∗∗∗∗
to save and move on to program Paper Type or
press MENU 2 seconds to quit the programming menu.
It varies the arrangement of the fields when you vary the
distance to vary the output distance. And the same label
programmed with or without backspace is printed differently.
11.4.1.5.Type of Paper [ 7 4 1 5 ]
With this parameter, you choose the type of paper with which
the label printer is going to work, that is:
‘0’ - Self-adhesive label paper.
‘1’ - Continuous paper without collector.
‘2’ - Continuous paper with collector.
‘3’ – Linerless (See linerless Appendix).
Linerless systems is only available in M-525
Press
∗∗∗∗
to save and move on to program the Level 1 Totals
Format or press MENU
2 seconds to quit the programming
menu.
11.4.1.6.Total format Level 1 [ 7 4 1 6 ]
The value of this parameter indicates the format with which
the level 1 total labels are to be printed. If the value is 0, the
format of the labels that have been issued will be used.
Press
∗∗∗∗
to save and enter Level 2 Totals Format
programming or press MENU 2 seconds to exit the
programming menu.
11.4.1.7.Total Format Level 2 [ 7 4 1 7 ]
The value of this parameter indicates the format with which
the level 2 total labels are to be printed. If the value is 0, the
format of the labels that have been issued will be used.
Press
∗∗∗∗
to save and enter Level 3 Totals Format
programming or press MENU 2 seconds to exit the
programming menu.
11.4.1.8.Total Format Level 3 [ 7 4 1 8 ]
The value of this parameter indicates the format with which
the level 3 total labels are to be printed. If the value is 0, the
format of the labels that have been issued will be used.
Press
∗∗∗∗
to save and enter EAN format of Level 1 Totals
programming or press MENU 2 seconds to exit the
programming menu.
Summary of Contents for Mistral M-510
Page 2: ......
Page 8: ......
Page 139: ...500 Range 49 M500WMEN25 131 15 6 FORMATS 15 6 1 label formats...
Page 140: ...USER S MANUAL 49 M500WMEN25 132...
Page 163: ......
Page 165: ......