CHARACTERISTICS
■
Customised radio code
■
Configuration of the receiver using a bar of 10 microswitches
■
Fixing accessories supplied
■
Connection by screw terminals, wire cross-section 2.5 mm2 maximum (wires not supplied)
■
Mains power supply 230 V AC (50 Hz)
■
Controlled 230 V AC output (50 Hz)
■
Relay breaking capacity: 5 A for 230 V AC
■
Maximum power authorised: 1000 W for 230 V AC
Note:
●
If you want to control a motor, relay, transformer or neon light, the output must be protected with a
resistor and capacitor (see connection chapter)
●
If you want to control a class I device (a device requiring an earth connection), the earth-device
connection must be made.
INSTALLATION PRECAUTIONS
■
Install it:
●
inside the house only,
●
in such a way that an intruder cannot reach it without triggering the alarm (if it is added to a DIA-
GRAL security system),
●
antenna facing down,
●
more than 5 m from your control panel, telephone dialler, alarm siren or any
other receiver,
more than 1.5m from the device to be controlled, if it is likely to generate interfe-
rence (neon, flash, etc.),
●
high up (approx. 2.2 m),
●
connected to a 230 V - 50 Hz protected and isolatable mains power supply.
■
Do not install it:
●
directly on a metal wall,
●
too close to an electric device generating interference: electricity meter, telephone installation, com-
puter, etc.,
●
less than 1 m from a water pipe,
●
in a room with a water supply.
Warning:
switch off the power supply before any intervention.