- 52 -
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
Plug-In series
Amplifiers from the Plug-in series offer RS485 and RS232 connectivity. For the RS485 connection,
use
. The Plug-in connector is positioned on the rear panel of the Control Unit, type DB9
female, designated ‘RS485’.
On the front panel of the Control unit, there is a connector designated RS232. The Plug-in is
accessible from this connector, but this is not recommended. Leave this connector available to
service the transmitter. These two connectors share the same UART. When RS232 is used, the other
connector (RS485) is disabled internally. The DB2003 considers this as Link Loss and if the alarm is
enabled, notifications are sent.