For some signals, both high and low threshold are monitored (Forward Power, Temperature,
Modulation), while for others - only high threshold is (Reflected and Unbalanced Power). A
notification is sent whenever the value passes the threshold (alarm activation) and upon its return to
normal status (Idle).
An alarm notification is also sent in the case of an event such as loss of connection with the
monitored device. For this type of alarm, no threshold or delay is set. For some events, it is not
necessary to send a notification for the return to normal values – for example that is the case with
power change.
To set up an email notification, the following must be fulfilled:
• the [E-mail] button in the Notifications for the alarm must be enabled;
• e-mail notification must be enabled for the entire Telemetry Port;
•
a receiver must be entered in
To set up an SNMP trap notification, the following must be fulfilled:
• the [SNMP] button in the Notifications for the alarm must be enabled;
• SNMP trap notification must be enabled for the entire Telemetry Port;
•
a receiver must be entered in
Settings> Device> SNMP Agent> Manager IP
.