- 12 -
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
MONITORED DEVICES
DB2003 can be used with the following RVR Elettronica devices:
•
Transmitter/Exciter series: PTX_LCD, PTX_DDS, PTX_LCD_DSP, TEX_LCD and Blues;
• Power Amplifiers: PJ, Plug-in KPS-CA and Barracuda;
•
Change-over Units.
The monitored device must be connected through a cable to the DB2003, with the relevant
Telemetry Port set up as specified in the
“Telemetry Port Settings” on page 24
You will find details on the cables for connecting the DB2003 to the monitored device in
SETTING SCENARIO
DB2003 has several communication interfaces: 2х RS232, RS485 half duplex and I
2
C.
DB2003 has three Telemetry Ports. Each Telemetry Port can use any of the available interfaces to
connect to its corresponding monitored device. Multiple scenarios are possible, with the monitored
devices not exceeding 3 (the number of Telemetry Ports).
Some monitored devices can be connected via RS232 and/or I
2
C (PTX_LCD). Plug-in KPS-CA
can be connected via RS485 or RS232, but the preferred interface is RS485, so RS232 can be available
to service the transmitter.
In accordance with their installation, the client must make the necessary cables. Details on Cables
and connectors can be found in
DB2003 is able to send alarm notifications via SMS using a GSM modem, which is purchased
additionally. The Modem is connected to communication port “COM1” and upon activating it, that
port cannot be used to connect to a monitored device.
Depending on the selected operation mode, the DB2003 can be used for:
•
passive monitoring of the monitored device, without affecting it;
•
remote control of the monitored device through commands sent by an operator;
•
automatic control of the monitored device by a set schedule – change of power.
DAYPARTS
DB2003 allows users to set up a weekly schedule to manage the power of the monitored device.
Not all monitored device series can be managed. This functionality is available for PTX_LCD, PTX_
LCDDSP, PTX_DDS ,TEX_LCD, Blues, Plug-in KPS-CA and Barracuda.
Users can set two levels – Low Power and Full Power. When there is an active Daypart, a command
is sent to manage the power level to Low Power. When there is no active Daypart, a command is sent
to manage the power level to Full Power.
Further details on the setup and use of Dayparts are available in
.